← Back to catalogue

On-X Aortic Heart Valve with Anatomic Sewing Ring

FDA UDI

Class III (US FDA UDI)

by On-X Life Technologies, Inc.

Identity

Trade Name
On-X Aortic Heart Valve with Anatomic Sewing Ring FDA UDI
Generic Name
Aortic bi-leaflet mechanical heart valve prosthesis FDA UDI
Device Name
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position. The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity. The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation. The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only. Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral). FDA UDI
Model / Reference
ONXAN-25 FDA UDI
Description
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position. The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity. The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation. The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only. Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral). FDA UDI

Identifiers

Primary DI / UDI-DI
00851788001624 FDA UDI
PMA Number
P000037 FDA UDI
FDA Product Code
LWQ FDA UDI
GMDN Term
Aortic bi-leaflet mechanical heart valve prosthesis FDA UDI

Classification

Device Class
Class III FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

Yes

FDA UDI

Single Use

Yes

FDA UDI

Implantable

Yes

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

No

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI
MRI Safety
MR Conditional FDA UDI

Dimensions & Sizes

Size
Outer Diameter — 25 Millimeter FDA UDI

Category: Aortic bi-leaflet mechanical heart valve prosthesis

On-X Aortic Heart Valve with Anatomic Sewing Ring by On-X Life Technologies, Inc. — Class III — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Aortic bi-leaflet mechanical heart valve prosthesis.

Cleared under the same submission

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 0be89d66-253d-4f6a-8c51-8fee011d2f6c 35 fields · synced Jun 6, 2026