Opn NC
Part of a family of 20 devices: see the family page
Ref 250-010-004
Opn NC (250-010-004) is a coronary angioplasty balloon catheter (EU MDR Class III; FDA Class II; FDA product code LOX, Catheters, Transluminal Coronary Angioplasty, Percutaneous) made by SIS Medical AG, registered in EUDAMED on 25 Aug 2022 (Basic UDI-DI 764014257OPN_NCKM) with CE/MDR certificate 44911221715 valid until 27 Feb 2030, cleared under FDA 510(k) K212393 on 14 Mar 2022 and listed in FDA GUDID since 12 Dec 2022 (UDI-DI 07640142570530), active as of 25 Oct 2026.
Active
CE MDR 510(k)
Valid until
27 Feb 2030
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number44911221715 | Date22 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07640142570530 | Date12 Dec 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK212393 | Date14 Mar 2022 | StatusActive |
Official records
- EUDAMED public site 764014257OPN_NCKM
- AccessGUDID record 07640142570530
- FDA 510(k) database K212393
From the FDA record
- Device description
- OPN NC Ø2.5x10 PTCA catheters
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 764014257OPN_NCKM registered 25 Aug 2022 Active
- FDA 510(k) K212393 decided 14 Mar 2022 Active
- FDA GUDID UDI-DI 07640142570530 listed 12 Dec 2022 Listed
Certificates
- 44911221715 Active
Quality management system EU MDR
- Certifier
- TÜV NORD CERT GmbH 0044
- Issued
- 22 May 2026
- Expires
- 27 Feb 2030
- Reason
- Other
- 44912221715 Active
Technical documentation EU MDR
- Certifier
- TÜV NORD CERT GmbH 0044
- Issued
- 22 May 2026
- Expires
- 27 Feb 2030
- Reason
- Mnf ar change
Timeline
- Cleared FDA 510(k) K212393
- Registered EUDAMED 764014257OPN_NCKM
- Listed FDA GUDID 07640142570530
- Certificate issued EUDAMED 44911221715
- Certificate issued EUDAMED 44912221715
- Certificate expires EUDAMED 44911221715
- Certificate expires EUDAMED 44912221715
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Coronary angioplasty balloon catheter, basic
- Model / reference
- 250-010-004
- Primary DI / UDI-DI
- 07640142570530
- Basic UDI-DI
- 764014257OPN_NCKM
- Direct marketing DI
- 07640142570530
- 510(k) Number
- FDA product code
- LOX
- EMDN code
- C010401020101 Ptca balloon dilation catheters
- GMDN term
- Coronary angioplasty balloon catheter, basic
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 870.5100
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Manufacturer details
- EUDAMED SRN
- CH-MF-000015821
- Authorised representative
- EUMEDIQ GmbH DE-AR-000007809
Similar devices in this category
Other devices filed under PTCA BALLOON DILATION CATHETERS.
- Coronary angioplasty catheter Rapid Exchange, River CBR2.00X30140 by Balton Sp. z o.o.
- Sapphire II (RX) 234-R-1720J by OrbusNeich Medical (Shenzhen) Co.,Ltd
- Mozec™ SEB MOZS35009 by Meril Life Sciences Pvt. Ltd.
- Lineage™ NC LNCD45015 by Meril Life Sciences Pvt. Ltd.
- NEON BS-40020 by Kaneka Corp.
- Performa® 00884450362235 612538ULT2/A by Merit Medical Systems, Inc.
- IKAZUCHI Zero ZE-6-300 by Kaneka Corp.
- Scoreflex NC Scoring PTCA Catheter 635-104-1U by OrbusNeich Medical (Shenzhen) Co.,Ltd
- Performa® 00884450162019 5RPL125/A by Merit Medical Systems, Inc.
- Sapphire II PRO 220-103-5U by OrbusNeich Medical, B.V.