Skip to content

Optical Tracking System (OTS)

by Radionics, Inc. 2 variants

510(k) K990632

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK990632 Date29 Apr 1999ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
HAW
Device Class
Class II
Regulation
21 CFR Part 882.4560
Advisory Committee
Neurology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Optical Tracking System (OTS) is a stereotaxic instrument utilizing optical tracking technology for intraoperative navigation, serving as a graphical planning tool. It employs optical sensors and tracking markers to facilitate precise spatial orientation and real-time visualization during surgical procedures, particularly in neurology applications.

The system is supplied as a hardware-software combination, designed for use in operating rooms where intraoperative navigation is required. It is classified as a reusable device under FDA 510(k) clearance (K990632) and falls under product code HAW, with a traditional review pathway. No specific sterility or MRI safety information is provided in the available data.

Other devices from Radionics, Inc.

See all devices from Radionics, Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of surgical procedures is the Optical Tracking System (OTS) primarily designed to assist with, and how does it work during those procedures?

    The Optical Tracking System (OTS) is designed for intraoperative navigation, particularly in neurology applications, where precise spatial orientation is critical. It uses optical sensors and tracking markers to provide real-time visualization and guidance during surgery. By tracking the position of surgical instruments and anatomical landmarks, the OTS helps surgeons maintain accuracy and alignment, reducing the risk of error in procedures where millimeter precision matters.

  • Is the Optical Tracking System (OTS) intended for single-use or reusable applications, and what does that mean for maintenance and upkeep?

    The OTS is classified as a reusable device, meaning it is designed to be used multiple times after proper cleaning, disinfection, and maintenance. Since it is not sterile by default, facilities must follow established protocols for reprocessing to ensure safety and functionality between uses. This includes regular calibration checks, as optical tracking systems can be sensitive to environmental factors like dust or misalignment.

  • What hardware and software components does the OTS include, and how is it typically deployed in an operating room?

    The OTS is supplied as a hardware-software combination, meaning it includes both physical tracking equipment (such as cameras, sensors, and markers) and accompanying software for navigation and visualization. It is designed for use in operating rooms where intraoperative guidance is required. The system requires proper setup, including mounting tracking cameras and attaching markers to surgical instruments or patient anatomy, to enable real-time spatial tracking during procedures.

  • Are there any specific storage requirements for the Optical Tracking System (OTS) to ensure its longevity and performance?

    While the provided data does not specify exact storage conditions, reusable medical devices like the OTS generally require protection from environmental contaminants (e.g., dust, moisture) and physical damage. Facilities should store the system in a clean, dry environment when not in use, following manufacturer guidelines for maintenance to preserve optical clarity and calibration accuracy. Proper handling and storage help extend the device’s operational lifespan.