Skip to content

Optima Advance

by GE Hangwei Medical Systems Company Ltd.

Optima Advance is a Class II device made by GE Hangwei Medical Systems Company Ltd., cleared under FDA 510(k) K123596 on 8 Feb 2013 and listed in FDA GUDID since 23 Jan 2020 (UDI-DI 00840682147415), active as of 23 Oct 2026. 5 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

510(k) K123596

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00840682147415 UDI-DI Date23 Jan 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK123596 Date8 Feb 2013DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K123596 decided 8 Feb 2013 Active
  • FDA GUDID UDI-DI 00840682147415 listed 23 Jan 2020 Listed

Recalls

5 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-0604-2025 FDA Class II initiated 5 Nov 2024
    • Ongoing Z-0601-2025 FDA Class II initiated 5 Nov 2024

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    • Terminated Z-2585-2018 FDA Class II initiated 24 May 2018

    Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply).

    • Terminated Z-2185-2017 FDA Class II initiated 19 May 2017

    It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed.

    • Terminated Z-0840-2014 FDA Class II initiated 9 Oct 2013

    There is an issue with the Manual Film Composer feature on some CT products. There is an opportunity, while following a specific workflow, to create a film image with one patient's images and another patient's name in the footer. This is also an issue when within Manual Film Composer, if a color image is selected for printing, another patient's black and white image appears in the preview screen

Timeline

7 dated events

  1. Cleared FDA 510(k) K123596
  2. Recall initiated FDA recalls Z-0840-2014
  3. Recall initiated FDA recalls Z-2185-2017
  4. Recall initiated FDA recalls Z-2585-2018
  5. Listed FDA GUDID 00840682147415
  6. Recall initiated FDA recalls Z-0604-2025
  7. Recall initiated FDA recalls Z-0601-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Optima
Generic name
Full-body CT system
Model / reference
Advance
Primary DI / UDI-DI
00840682147415
510(k) Number
FDA product code
JAK
GMDN term
Full-body CT system
Device class
Class II
Regulation number
892.1750
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Full-body CT system.

Other devices from GE Hangwei Medical Systems Company Ltd.

  • Operator Console

    Class II
  • Optima CT680 Expert Open recall

    Class II
  • Revolution Ascend Sliding

    Class II
  • 5455274-100 Open recall

    Class II

See all devices from GE Hangwei Medical Systems Company Ltd. →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)