Optima Coil System OPTI0520CSF10

by Balt USA LLC

Optima Coil System OPTI0520CSF10 is a neurovascular embolization coil (FDA Class II) made by Balt USA LLC, cleared under FDA 510(k) K200030 on 1 Feb 2020 and listed in FDA GUDID since 28 Feb 2020 (UDI-DI 00818053024801), active as of 23 Oct 2026. 5 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

510(k) K200030

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00818053024801 UDI-DI Date28 Feb 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK200030 Date1 Feb 2020DecidedStatusActive

Official records

From the FDA record

Device description
The Optima Coil System is indicated for endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations (AVMs) and arteriovenous fistulae. The Optima Coil System is also indicated for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolization in the peripheral vasculature. The Optima Coil System comprises of implant coil and a pusher assembly. The Optima Coil System is designed fr use with the XCEL Detachment Controller. The Optima coil is detached thermally with the XCEL Detachment Controller.
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K200030 decided 1 Feb 2020 Active
  • FDA GUDID UDI-DI 00818053024801 listed 28 Feb 2020 Listed

Recalls

5 recalls · 5 ongoing · FDA

    • Ongoing Z-1988-2025 FDA Class II initiated 8 May 2025

    Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification.

    • Ongoing Z-1041-2024 FDA Class II initiated 3 Jan 2024 UDI-DI 00818053024801 listed

    Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli.

    • Ongoing Z-0103-2023 FDA Class II initiated 7 Sep 2022

    Product pouch label does not match up with carton label

    • Ongoing Z-1680-2022 FDA Class II initiated 26 Jul 2022

    Products were released to customers prior to the approval and release of a test report authorizing the use of an existing material from an alternate supplier.

    • Ongoing Z-0660-2022 FDA Class II initiated 4 Jan 2022

    Due to Label/Pouch mix-up. Pouches incorrectly labeled. Incorrect shelf carton label or pouch label due to inadequate manufacturing line clearance. As a result of this labeling mix-up, there is the possibility of inadvertently selecting the incorrect coil size for the procedure potentially causing some harms like vessel damage, an inability to treat with said device and potential rupture of the aneurysm.

Timeline

7 dated events

  1. Cleared FDA 510(k) K200030
  2. Listed FDA GUDID 00818053024801
  3. Recall initiated FDA recalls Z-0660-2022
  4. Recall initiated FDA recalls Z-1680-2022
  5. Recall initiated FDA recalls Z-0103-2023
  6. Recall initiated FDA recalls Z-1041-2024
  7. Recall initiated FDA recalls Z-1988-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Optima Coil System
Generic name
Neurovascular embolization coil
Model / Ref / Catalog
OPTI0520CSF10
Primary DI / UDI-DI
00818053024801
510(k) Number
FDA product code
KRD, HCG
GMDN term
Neurovascular embolization coil
Device class
Class II
Regulation number
870.3300, 882.5950
GUDID distribution status
In Commercial Distribution
MRI safety
MR Conditional

Similar devices

Other devices filed under FDA product code KRD (Device, Vascular, For Promoting Embolization).

Other devices from Balt USA LLC

See all devices from Balt USA LLC →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)