Skip to content

Optimized Ortho Positioning (OPS) System 1248-0033

by Optimized Ortho Pty Ltd

Ref 1248-0033Model OPS Acetabular Reusable Instruments

Optimized Ortho Positioning (OPS) System 1248-0033 is an orthopaedic surgical procedure kit (EU MDR Class I; FDA Class II) made by Optimized Ortho Pty Ltd, registered in EUDAMED on 7 Oct 2026 (Basic UDI-DI 50553438INSTRFIXA1RB4), cleared under FDA 510(k) K152893 on 3 Jun 2016 and listed in FDA GUDID since 11 Feb 2020 (UDI-DI 09351327000619), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 24 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K152893

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number50553438INSTRFIXA1RB4 Basic UDI-DI 09351327000619UDI-DIDate7 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number09351327000619 UDI-DI Date11 Feb 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK152893 Date3 Jun 2016DecidedStatusActive

Official records

From the FDA record

Device description
Pelvic Screw Long
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 50553438INSTRFIXA1RB4 registered 7 Oct 2026 Active
  • FDA 510(k) K152893 decided 3 Jun 2016 Active
  • FDA GUDID UDI-DI 09351327000619 listed 11 Feb 2020 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K152893
  2. Listed FDA GUDID 09351327000619
  3. Registered EUDAMED 50553438INSTRFIXA1RB4

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Pelvic Screw Long EUDAMED
Optimized Ortho Positioning (OPS) System GUDID
Generic name
Orthopaedic surgical procedure kit, non-medicated, reusable
Device name
Fixation Instruments
Model / reference
1248-0033, OPS Acetabular Reusable Instruments
Primary DI / UDI-DI
09351327000619
Basic UDI-DI
50553438INSTRFIXA1RB4
510(k) Number
FDA product code
LZO, LWJ, MEH
EMDN code
L0919 Orthopaedic and traumatological surgery instrument kits, reusable
GMDN term
Orthopaedic surgical procedure kit, non-medicated, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3353, 888.3360
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II
Sterilise before useEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Sterilise before use UDI-DI 09351327000619: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ORTHOPAEDIC AND TRAUMATOLOGICAL SURGERY INSTRUMENT KITS, REUSABLE.

Other devices from Optimized Ortho Pty Ltd

See all devices from Optimized Ortho Pty Ltd →

Properties

  • Sterilise before use NoEUDAMEDYesGUDID
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (21, all answered No)