OptosAdvance 4.0 Software
by Optos plc United Kingdom EUDAMED510(k)
510(k) K162039
Product code NFJ
Overview
The OptosAdvance 4.0 Software is a digital imaging system designed for ophthalmic use, specifically for retinal imaging and management. Classified as an image management system under FDA’s device nomenclature, it captures wide-field retinal scans to assist in the diagnosis, monitoring, and documentation of retinal conditions. This software integrates with the Optos retinal camera to provide high-resolution images of the retina, including the peripheral regions often missed by traditional imaging techniques.
This software is supplied as a standalone digital solution for use in clinical radiology settings, requiring compatible hardware for operation. It is intended for single-use per session, with no indication of sterility requirements, and is not classified as MRI-safe or unsafe. The system supports multiple image formats and is authorised under FDA’s 510(k) clearance (K162039) and the EU’s Medical Device Regulation (MDR). No specific storage conditions are detailed beyond standard IT infrastructure requirements.
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE 510(k) | NumberK162039 | Date8 Feb 2017 | StatusActive |
| European Union | CE/MDR EUDAMED | Number— | Date— | StatusActive |
Coverage
- Active
- Not covered
- European Union
- United States
Specification
- 510(k) Number
- FDA Product Code
- NFJ
- FDA applicant
- Optos Plc.
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.2050
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Other devices from Optos plc
Questions
What clinical setting is the OptosAdvance 4.0 Software designed for, and how does it differ from traditional retinal imaging methods?
The OptosAdvance 4.0 Software is specifically designed for clinical radiology settings, particularly in ophthalmology, to capture wide-field retinal scans. Unlike traditional imaging techniques that often miss peripheral retinal regions, this software integrates with the Optos retinal camera to provide high-resolution images of the entire retina, including areas typically overlooked. This makes it particularly useful for diagnosing, monitoring, and documenting retinal conditions that may extend beyond the central field of view.
Is the OptosAdvance 4.0 Software reusable or intended for single-use per session, and what are the implications for clinical workflow?
The OptosAdvance 4.0 Software is intended for single-use per session, meaning it is not designed to be reused across multiple patients. This approach simplifies workflow by eliminating the need for reprocessing or sterilization between uses, reducing potential contamination risks. Clinicians should ensure a fresh installation or session setup for each patient to maintain optimal performance and hygiene standards.
What hardware compatibility and IT infrastructure requirements should be considered when implementing the OptosAdvance 4.0 Software?
The OptosAdvance 4.0 Software is a standalone digital solution that requires compatible hardware, specifically the Optos retinal camera, for operation. Beyond this, the software relies on standard IT infrastructure requirements for installation and functionality. Ensure your clinical environment meets these baseline IT needs, such as appropriate computing resources and network connectivity, to support seamless integration and performance.
Does the OptosAdvance 4.0 Software have any specific storage or environmental conditions that must be met?
The OptosAdvance 4.0 Software does not specify unique storage conditions beyond standard IT infrastructure requirements. This means it should be stored in a typical clinical IT environment, such as a server or workstation, following general best practices for digital systems—such as protecting against physical damage, power fluctuations, and unauthorized access—to ensure reliability and data integrity.
What regulatory pathways has the OptosAdvance 4.0 Software undergone, and how does this affect its use in different markets?
The OptosAdvance 4.0 Software has been authorized through the FDA’s 510(k) clearance process (K162039) and the EU’s Medical Device Regulation (MDR). This means it is legally marketable in the United States and the European Economic Area under these respective regulatory frameworks. Clinicians should confirm local compliance requirements and consult with regulatory authorities or legal advisors to ensure adherence to regional regulations when implementing the software.
Properties & raw data
Show properties, registry sources and raw records
Sources (2)
- FDA 510(k) K162039
- EUDAMED