Skip to content

Orfit Industries 25101/16MI+N/NH

by Orfit Industries NV

Part of a family of 84 devices: see the family page

Ref 25101/16MI+N/NHModel Head Positioning System

Orfit Industries 25101/16MI+N/NH is a radiological whole-body positioner (EU MDR Class I; FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Orfit Industries NV, registered in EUDAMED on 4 Nov 2026 (Basic UDI-DI 5420028700244Y), cleared under FDA 510(k) K171734 on 25 Jul 2017 and listed in FDA GUDID since 7 Dec 2022 (UDI-DI 05420028700846), active as of 25 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 25 Oct 2026

Documents

None, self-declared

Class I: no certifier involved

510(k) K171734

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number5420028700244Y Basic UDI-DI 05420028700846UDI-DIDate4 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number05420028700846 UDI-DI Date7 Dec 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK171734 Date25 Jul 2017DecidedStatusActive

Official records

From the FDA record

Device description
3pt Paediatric Mask for HP PRO Solution - Medium Nanor 1.6 mm Micro+, No Nose Hole
MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 5420028700244Y registered 4 Nov 2026 Active
  • FDA 510(k) K171734 decided 25 Jul 2017 Active
  • FDA GUDID UDI-DI 05420028700846 listed 7 Dec 2022 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Timeline

3 dated events

  1. Cleared FDA 510(k) K171734
  2. Listed FDA GUDID 05420028700846
  3. Registered EUDAMED 5420028700244Y

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
3pt Paediatric Mask for HP PRO EUDAMED
Orfit Industries GUDID
Generic name
Radiological whole-body positioner
Model / reference
25101/16MI+N/NH, Head Positioning System
Primary DI / UDI-DI
05420028700846
Basic UDI-DI
5420028700244Y
510(k) Number
FDA product code
IYE
EMDN code
Z11010180 Linear accelerators - hardware accessories
GMDN term
Radiological whole-body positioner
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.5050
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution
MRI safety
MR Safe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under LINEAR ACCELERATORS - HARDWARE ACCESSORIES.

Other devices from Orfit Industries NV

See all devices from Orfit Industries NV →

Properties

  • Single use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (21, all answered No)