Orfit Industries 33733/16MI/12MI+N

by Orfit Industries NV

Part of a family of 76 devices: see the family page

Ref 33733/16MI/12MI+NModel Mask

Orfit Industries 33733/16MI/12MI+N is a head/neck procedure positioner (EU MDR Class I; FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Orfit Industries NV, registered in EUDAMED on 6 Oct 2026 (Basic UDI-DI 5420028700214S), cleared under FDA 510(k) K131795 on 26 Sep 2013 and listed in FDA GUDID since 7 Dec 2022 (UDI-DI 05420028751947), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 24 Oct 2026

Documents

None, self-declared

Class I: no certifier involved

510(k) K131795

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number5420028700214S Basic UDI-DI 05420028751947UDI-DIDate6 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number05420028751947 UDI-DI Date7 Dec 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK131795 Date26 Sep 2013DecidedStatusActive

Official records

From the FDA record

Device description
5pt Hybrid HNS Open Face Mask Eff 16MI - Nanor 12MI+
MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 5420028700214S registered 6 Oct 2026 Active
  • FDA 510(k) K131795 decided 26 Sep 2013 Active
  • FDA GUDID UDI-DI 05420028751947 listed 7 Dec 2022 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Timeline

3 dated events

  1. Cleared FDA 510(k) K131795
  2. Listed FDA GUDID 05420028751947
  3. Registered EUDAMED 5420028700214S

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
5pt Hybrid HNS Open Face Mask Eff 16MI - Nanor 12MI+ EUDAMED
Orfit Industries GUDID
Generic name
Head/neck procedure positioner
Device name
Raycast® High Precision - Efficast® Masks, Nanor Masks and Hybrid Masks with Nanor for Patient Immobilisation -Head, Neck and Shoulder
Model / reference
33733/16MI/12MI+N, Mask
Primary DI / UDI-DI
05420028751947
Basic UDI-DI
5420028700214S
510(k) Number
FDA product code
IYE
EMDN code
V0804 PATIENT IMMOBILISERS (in diagnostic or therapeutic procedures)
GMDN term
Head/neck procedure positioner
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.5050
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution
MRI safety
MR Safe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under PATIENT IMMOBILISERS (in diagnostic or therapeutic procedures).

Other devices from Orfit Industries NV

See all devices from Orfit Industries NV →

Properties

  • Single use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (21, all answered No)