Skip to content

Orthex Tool RB-180B

by Vilex in Tennessee, Inc.

Orthex Tool RB-180B is an external orthopaedic fixation system (FDA Class II; FDA product code KTT, Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component) made by Vilex in Tennessee, Inc., cleared under FDA 510(k) K151881 on 24 Mar 2016 and listed in FDA GUDID since 26 Jul 2019 (UDI-DI 00841731121516), active as of 22 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

510(k) K151881

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00841731121516 UDI-DI Date26 Jul 2019ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK151881 Date24 Mar 2016DecidedStatusActive

Official records

From the FDA record

Device description
X-Ray Ball Bridge, 180mm
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K151881 decided 24 Mar 2016 Active
  • FDA GUDID UDI-DI 00841731121516 listed 26 Jul 2019 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-0277-2023 FDA Class II initiated 12 Sep 2022 on shared 510(k) K151881

    Bolt breakage on the head or threaded portion, which may cause loss of strut continuity with frame. This may cause loss of deformity correction and/or disruption of bone regeneration.

    • Ongoing Z-1678-2022 FDA Class II initiated 29 Jun 2022

    Manufacturing variance near transition of tip is increasing the likelihood the wire tip may fracture. The fractured tip may be retained in the patient. Retrieval attempts may be made which could result in a delay of surgery and potentially damage soft tissue and increase healing time

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K151881
  2. Listed FDA GUDID 00841731121516
  3. Recall initiated FDA recalls Z-1678-2022
  4. Recall initiated FDA recalls Z-0277-2023

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Orthex Tool
Generic name
External orthopaedic fixation system, single-use
Model / reference
RB-180B
Primary DI / UDI-DI
00841731121516
510(k) Number
FDA product code
KTT
GMDN term
External orthopaedic fixation system, single-use
Device class
Class II
Regulation number
888.3030
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices in this category

Other devices filed under External orthopaedic fixation system, single-use.

Other devices from Vilex in Tennessee, Inc.

See all devices from Vilex in Tennessee, Inc. →

Properties

  • Sterilise before use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (11, all answered No)