OSCAR 15(Unique FD)
Ref 107510(k) K172180
OSCAR 15(Unique FD) (107) is a portable general-purpose fluoroscopic x-ray system (EU MDD Class IIb; FDA Class II) made by Genoray Co., Ltd., registered in EUDAMED on 14 Aug 2024 (Basic UDI-DI B-08809244061219), cleared under FDA 510(k) K172180 on 9 Feb 2018 and listed in FDA GUDID since 11 Apr 2018 (UDI-DI 08809244061219), active as of 22 Oct 2026.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-08809244061219 08809244061219 | Date14 Aug 2024 | StatusActive |
| United States | GUDID listing GUDID | Number08809244061219 | Date11 Apr 2018 | StatusListed |
| United States | FDA 510(k)SESE 510(k) | NumberK172180 | Date9 Feb 2018 | StatusActive |
Official records
- EUDAMED public site B-08809244061219
- AccessGUDID record 08809244061219
- FDA 510(k) database K172180
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-08809244061219 registered 14 Aug 2024 Active
- FDA 510(k) K172180 decided 9 Feb 2018 Active
- FDA GUDID UDI-DI 08809244061219 listed 11 Apr 2018 Listed
Timeline
- Cleared FDA 510(k) K172180
- Listed FDA GUDID 08809244061219
- Registered EUDAMED B-08809244061219
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- United States
- European Union
Specification
- Trade name
- OSCAR 15(Unique FD) EUDAMEDGenoray GUDID
- Generic name
- Portable general-purpose fluoroscopic x-ray system, digital
- Model / reference
- 107 EUDAMEDOSCAR 15 GUDID
- Primary DI / UDI-DI
- 08809244061219
- Basic UDI-DI
- B-08809244061219
- 510(k) Number
- FDA product code
- JAA, OWB
- EMDN code
- Z11039009 Fluoroscopy devices
- GMDN term
- Portable general-purpose fluoroscopic x-ray system, digital
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1650
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Greece
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 107 | OSCAR 15 |
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- KR-MF-000021014
- Authorised representative
- Obelis s.a. BE-AR-000000106
Similar devices in this category
Other devices filed under FLUOROSCOPY DEVICES.
- GARION by Sg Healthcare Co, Ltd.
- ImagingRing r 1 by medPhoton GmbH
- Multitom Rax 10860700 by Siemens Healthcare GmbH
- ProxiDiagnost N90 706100 by Philips Medical Systems DMC GmbH
- OrthoScan Mobile DI Mini C-arm 1000-0005 by Ziehm-Orthoscan, Inc.
- Luminos dRF Max 10762471 by Siemens Healthcare GmbH
- Digital Radiography and Fluoroscopy System GMDN Code: 37679 by Beijing Wandong Medical Technology Co., Ltd.
- Smart-C 902-00001 by Turner Imaging Systems, Inc.
- GARION+ by Sg Healthcare Co, Ltd.
- CombiDiagnost R90 Rel 1.1 709031 by Philips Medical Systems DMC GmbH