OsteoMed 320-1012-SP-02
Ref 320-1012-SP-02
OsteoMed 320-1012-SP-02 is a device classified as Class IIa in the EU and Class II in the US made by Osteomed Corp., registered in EUDAMED on 6 Nov 2026 (Basic UDI-DI B-00845694073127) and listed in FDA GUDID since 22 Sep 2017 (UDI-DI 00845694073127), active as of 7 Nov 2026.
Active
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00845694073127 00845694073127 | Date6 Nov 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00845694073127 | Date22 Sep 2017 | StatusListed |
Official records
- EUDAMED public site B-00845694073127
- AccessGUDID record 00845694073127
Across registries
- EUDAMED Basic UDI-DI B-00845694073127 registered 6 Nov 2026 Active
- FDA GUDID UDI-DI 00845694073127 listed 22 Sep 2017 Listed
Timeline
- Listed FDA GUDID 00845694073127
- Registered EUDAMED B-00845694073127
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Acumed EUDAMEDOsteoMed GUDID
- Generic name
- General internal orthopaedic fixation system implantation kit
- Device name
- Instrument
- Model / Ref / Catalog
- 320-1012-SP-02
- Primary DI / UDI-DI
- 00845694073127
- Basic UDI-DI
- B-00845694073127
- FDA product code
- HWC
- EMDN code
- L091001 Instruments for insertion and extraction of materials for osteosynthesis, reusable
- GMDN term
- General internal orthopaedic fixation system implantation kit
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.3040
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Spain
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Supplied sterile | No | Yes |
| Sterilise before use | Yes | No |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Supplied sterile UDI-DI 00845694073127: EUDAMED states No, FDA GUDID states Yes.
- Sterilise before use UDI-DI 00845694073127: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under INSTRUMENTS FOR INSERTION AND EXTRACTION OF MATERIALS FOR OSTEOSYNTHESIS, REUSABLE.
- ACUMED 80-1335 by ACUMED LLC
- Non-sterile CMF (Cranio Maxillofacial Fixation) Instrument System IOC-124 by OSTEONIC CO., Ltd.
- SLIM-LOC 279600120 by Depuy Spine, Inc.
- ACUMED 80-4126 by ACUMED LLC
- Orthopaedic Large Distractor Instruments 394.420 by Synthes GmbH
- Zimmer® Natural Nail™ System 00-2490-003-04 by Zimmer, Inc.
- NCB® 02.00024.002 by Zimmer, Inc.
- EXPEDIUM VERSE 299704205 by MEDOS INTERNATIONAL SARL
- TMJ SYSTEM 24-6555TR by BIOMET MICROFIXATION, INC
- Pectus screwdriver 026-00010 by MedXpert GmbH