Skip to content

Osteonics Microsutered Femoral Componentes

by Osteonics Corp.

510(k) K926201

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK926201 Date22 Jun 1993ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
LPH
Device Class
Class II
Regulation
21 CFR Part 888.3358
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Osteonics Microsutered Femoral Component is a femoral replacement device designed for orthopedic hip arthroplasty. It is intended for use as part of a total hip prosthesis system, providing structural support and articulation within the hip joint. The component features a microsutered surface to enhance osseointegration and stability with the surrounding bone.

This device is supplied as a single-use, sterile implant intended for surgical use in orthopedic settings. It is classified under product code LPH and was cleared by the FDA through a Traditional 510(k) pathway in 1993. The component is not intended for MRI use and must be handled and stored according to manufacturer guidelines to maintain sterility and integrity prior to implantation.

Other devices from Osteonics Corp.

See all devices from Osteonics Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Osteonics Microsutered Femoral Component used for?

    This device is designed specifically for orthopedic hip arthroplasty, serving as part of a total hip prosthesis system. Its primary purpose is to provide structural support and facilitate articulation within the hip joint, while the microsutered surface promotes better osseointegration—meaning it encourages the surrounding bone to grow and bond more effectively to the implant for improved stability.

  • How is the Osteonics Microsutered Femoral Component supplied and prepared for use?

    The component is supplied as a single-use, sterile implant, meaning it is intended for one surgical procedure only and must remain unopened until use. Sterility and integrity must be maintained by following the manufacturer’s guidelines for handling and storage, which include keeping it in its original packaging until implantation.

  • Is the device reusable or intended for single-use only?

    This femoral component is explicitly intended for single-use only. Reuse is not recommended or supported by the manufacturer, as it could compromise sterility, structural integrity, or performance. Single-use ensures patient safety and compliance with regulatory standards.

  • What distinguishes the microsutered surface of this femoral component?

    The microsutered surface is a textured design engineered to enhance osseointegration—the process where bone grows directly into the implant. This texture increases the surface area for bone attachment, improving stability and longevity of the hip prosthesis compared to smoother alternatives.

  • Can this femoral component be used in MRI procedures?

    No, the Osteonics Microsutered Femoral Component is explicitly not intended for MRI use. MRI scans involve strong magnetic fields and radio waves that could potentially affect metallic implants, posing risks to both the patient and the imaging equipment. Always verify compatibility with the manufacturer’s guidelines before any MRI procedure.