Omnifit AD-HA Hip Stem Series
510(k) K941366
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK941366 | Date6 Jun 1995 | StatusActive |
Recalls
-
- Terminated Z-0902-2009
Stryker Orthopaedics became aware of a visual defect in certain blister packages of certain devices.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Osteonics Omnifit Ad-Ha Hip Stem Series
- 510(k) Number
- FDA Product Code
- MEH
- Device Class
- Class II
- Regulation
- 21 CFR Part 888.3353
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Omnifit AD-HA Hip Stem Series is a Hydroxyapatite-Coated Hip Prosthesis (Device Type: MEH), designed for use in total hip arthroplasty. It features a modular, press-fit stem intended to enhance primary stability and osseointegration through the application of hydroxyapatite coating on its surface. This coating promotes bone growth and fixation, reducing the risk of loosening over time. The series includes various stem designs tailored to accommodate different femoral anatomies and surgical approaches.
This device is supplied as a sterile, single-use implant intended for use in orthopedic surgical settings. It is regulated under FDA 510(k) clearance (K941366) and falls under the Orthopedic (OR) advisory committee classification. The stems are available in multiple sizes and configurations to match patient-specific requirements. Storage and handling must comply with sterile medical device protocols to ensure integrity prior to surgical use. No additional regulatory status beyond the stated FDA clearance is implied.
Other devices from Osteonics Corp.
Questions
AI-generated answers, 1 Oct 2026
What is the Omnifit AD-HA Hip Stem Series used for?
The Omnifit AD-HA Hip Stem Series is designed specifically for total hip arthroplasty (replacement surgery). Its modular, press-fit stem with hydroxyapatite coating enhances primary stability and promotes bone growth, reducing the risk of loosening over time. The coating encourages osseointegration—direct bonding between bone and the implant—while the modular design allows customization to fit diverse femoral anatomies and surgical approaches.
How is the Omnifit AD-HA Hip Stem Series supplied and prepared for use?
The device is supplied as a sterile, single-use implant, ensuring compliance with medical device sterility standards. It must be handled using sterile techniques to maintain its integrity before surgical use. The modular components are pre-packaged to prevent contamination, and the manufacturer’s storage guidelines (e.g., protected from moisture/damage) must be followed until implantation.
Is the hydroxyapatite coating on this stem reusable, or is it intended for single-use?
The Omnifit AD-HA Hip Stem Series is explicitly designed for single-use only. Hydroxyapatite coatings, while biocompatible, are not intended for repeated surgical applications due to potential degradation, contamination risks, or loss of coating integrity. Single-use ensures patient safety and maintains the coating’s effectiveness in promoting osseointegration.
What sizes and configurations are available for this hip stem?
The series includes multiple stem designs and sizes tailored to accommodate different femoral anatomies and surgical approaches. Exact dimensions and configurations are detailed in the manufacturer’s surgical technique guide, which provides compatibility charts for proximal femur shapes, neck-shaft angles, and offset requirements. Consult the packaging or technical documentation for the specific models available in your region.
How should the Omnifit AD-HA Hip Stem Series be stored before use?
Storage must adhere to sterile medical device protocols to preserve the implant’s integrity. The device should be kept in its original, unopened packaging in a clean, dry environment protected from direct sunlight, extreme temperatures, or physical damage. Avoid exposure to chemicals or contaminants, and follow the manufacturer’s expiration date to ensure sterility and performance. Refrigeration is not required unless specified in the packaging instructions.