Skip to content

Owl 467-022/150/10

by Diros Technology, Inc.

Owl 467-022/150/10 is a medical device (FDA Class II; FDA product code GXI, Probe, Radiofrequency Lesion) made by Diros Technology, Inc., cleared under FDA 510(k) K102566 on 3 Jun 2011 and listed in FDA GUDID since 1 Sep 2016 (UDI-DI 00825114002494), active as of 23 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 23 Oct 2026

Documents

510(k) K102566

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00825114002494 UDI-DI Date1 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK102566 Date3 Jun 2011DecidedStatusActive

Official records

From the FDA record

Device description
OWL STERILE SINGLE USE DISPOSABLE RF INSULATED CANNULA (22 Ga.), 145mm LONG, 10MM BARE TIP
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K102566 decided 3 Jun 2011 Active
  • FDA GUDID UDI-DI 00825114002494 listed 1 Sep 2016 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K102566
  2. Listed FDA GUDID 00825114002494

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Owl
Generic name
Percutaneous radio-frequency ablation probe cannula, single-use
Model / Ref / Catalog
467-022/150/10
Primary DI / UDI-DI
00825114002494
510(k) Number
FDA product code
GXI
GMDN term
Percutaneous radio-frequency ablation probe cannula, single-use
Device class
Class II
Regulation number
882.4725
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Similar devices in this category

Other devices filed under Percutaneous radio-frequency ablation probe cannula, single-use.

Other devices from Diros Technology, Inc.

See all devices from Diros Technology, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (9, all answered No)