Skip to content

P4-2 Transducer 10136143

by Siemens Medical Solutions USA, Inc.

Ref 10136143Model MDR_07_IIA_IQH_BTS LB A_ACDV_P4-2_10136143

P4-2 Transducer 10136143 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 8 Sep 2026 (Basic UDI-DI 0405686902444VR), cleared under FDA 510(k) K233610 on 12 Jun 2024 (2 earlier submissions) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 04056869005522), active as of 23 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

Recall on shared 510(k) K232617; other models may be affected

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0405686902444VR Basic UDI-DI 04056869005522UDI-DIDate8 Sep 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK233610 Date12 Jun 2024DecidedStatusActive
United StatesGUDID listing GUDID Number04056869005522 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686902444VR registered 8 Sep 2026 Active
  • FDA 510(k) K233610 decided 12 Jun 2024 Active· +2 more in the status table
  • FDA GUDID UDI-DI 04056869005522 listed 24 Sep 2016 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-3217-2024 FDA Class II initiated 15 Aug 2024 on shared 510(k) K232617

    If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliters using multiplier 100 instead of 1000, resulting values 10x smaller than actual, which could contribute misdiagnosis or negatively influence patient management

    • Ongoing Z-1601-2024 FDA Class II initiated 23 Feb 2024 on shared 510(k) K232617

    On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will display the LAST measured value, not min or max, which could contribute to patient condition misdiagnosis or negatively influence patient management decisions.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

7 dated events

  1. Cleared FDA 510(k) K150050
  2. Listed FDA GUDID 04056869005522
  3. Cleared FDA 510(k) K232617
  4. Recall initiated FDA recalls Z-1601-2024
  5. Cleared FDA 510(k) K233610
  6. Recall initiated FDA recalls Z-3217-2024
  7. Registered EUDAMED 0405686902444VR

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
P4-2 Transducer
Generic name
Extracorporeal ultrasound imaging transducer, hand-held
Device name
MDR_07_IIA_IQH_BTS Lb A_ACDV_P4-2_10136143
Model / reference
10136143, MDR_07_IIA_IQH_BTS LB A_ACDV_P4-2_10136143
Primary DI / UDI-DI
04056869005522
Basic UDI-DI
0405686902444VR
FDA product code
ITX
EMDN code
Z110402010301 Transcutaneous ultrasound sector probes (phased array), two–dimensional
GMDN term
Extracorporeal ultrasound imaging transducer, hand-held
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under TRANSCUTANEOUS ULTRASOUND SECTOR PROBES (PHASED ARRAY), TWO–DIMENSIONAL.

Other devices from Siemens Medical Solutions USA, Inc.

See all devices from Siemens Medical Solutions USA, Inc. →

Properties

  • Serial number
Other properties (24, all answered No)