Pacemaker, Model 229-01
by Intermedics, Inc. 510(k)
Active
510(k) K781738
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK781738 | Date7 Dec 1978 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 22 Oct 2026.
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Pacemaker, Model 229-01 is an Implantable Pacemaker Pulse-Generator, designed to regulate heart rhythm by delivering electrical impulses to the heart muscle when the natural pacemaker fails to do so. This device is classified as a Class III medical device, requiring stringent regulatory oversight due to its critical role in managing life-threatening cardiac conditions.
This pacemaker is intended for surgical implantation and is supplied sterile for single-use. It is regulated under FDA 510(k) clearance (K781738) and falls under the Cardiovascular advisory committee classification. The device is intended for use in controlled clinical settings, adhering to strict sterility and handling protocols to ensure patient safety and proper function.
Other devices from Intermedics, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Pacemaker, Model 229-01, and how does it function in the body?
The Pacemaker, Model 229-01, is designed to regulate heart rhythm by delivering electrical impulses to the heart muscle when the natural pacemaker fails. It is an implantable pulse-generator surgically placed in the body to ensure consistent heart contractions, which is critical for patients with life-threatening cardiac conditions where the heart’s natural rhythm is unreliable.
Is the Pacemaker, Model 229-01, intended for reuse or single-use, and how should it be handled to maintain sterility?
The Pacemaker, Model 229-01, is supplied sterile and intended for single-use only. Due to its critical role in patient safety, it must be handled under strict sterility protocols, adhering to controlled clinical settings to prevent contamination and ensure proper function after implantation.
What regulatory pathway was followed for the FDA clearance of this device, and which advisory committee was involved?
The Pacemaker, Model 229-01, was cleared through the FDA’s 510(k) pathway, specifically under the Traditional clearance type, with a decision of Substantially Equivalent. The device was reviewed by the Cardiovascular (CV) Advisory Committee, reflecting its classification as a Class III medical device due to its role in managing life-threatening cardiac conditions.
What medical specialty is primarily responsible for the use and oversight of this device?
The Pacemaker, Model 229-01, falls under the medical specialty of Cardiovascular care. This specialty encompasses the diagnosis and treatment of conditions affecting the heart and blood vessels, making it the primary focus for clinicians who implant, monitor, and manage patients using this device.