Skip to content

Pacemaker, Model DDP Electronic Circuit

by Arco Medical Products Co.

510(k) K782146

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESP Substantially Equivalent — Postmarket Surveillance · Traditional NumberK782146 Date27 Dec 1978ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESP Substantially Equivalent — Postmarket Surveillance

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Pacemaker, Model DDP Electronic Circuit is an implantable pacemaker pulse-generator designed to regulate heart rhythm by delivering electrical impulses to the heart muscle. This device is intended for patients experiencing bradycardia or other cardiac conduction disorders requiring artificial pacing.

This device is supplied sterile and intended for single-use implantation by qualified medical professionals. It is classified as a Class III medical device under FDA regulation 870.3610 and has received FDA 510(k) clearance (K782146) with postmarket surveillance requirements. The device is MRI-unspecified and must be handled according to standard sterile surgical procedures.

Other devices from Arco Medical Products Co.

See all devices from Arco Medical Products Co. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of heart conditions is this pacemaker designed to address, and how does it work?

    This pacemaker, Model DDP Electronic Circuit, is specifically designed to regulate heart rhythm for patients with bradycardia or other cardiac conduction disorders that require artificial pacing. It achieves this by delivering controlled electrical impulses to the heart muscle, helping to maintain a proper heartbeat when the natural conduction system is insufficient.

  • Is this device intended for reuse, or is it meant to be implanted once and discarded?

    The Model DDP Electronic Circuit is supplied sterile and intended for single-use implantation only. After use, it should not be reused, as this could compromise patient safety and device performance. It must be handled according to standard sterile surgical procedures during implantation.

  • What storage or handling precautions should be taken before implantation?

    Since this pacemaker is supplied sterile, it must be stored in its original packaging until ready for use to maintain sterility. The device should be handled using aseptic techniques, as it is intended for direct implantation by qualified medical professionals. Avoid exposure to moisture, contamination, or physical damage prior to use.

  • Can this pacemaker be used in patients who require MRI procedures, or are there specific restrictions?

    The Model DDP Electronic Circuit is labeled as MRI-unspecified, meaning its compatibility with MRI procedures is not explicitly defined. Clinicians should consult the manufacturer’s guidelines and follow strict protocols to ensure patient safety if MRI is required, as improper handling could pose risks to both the patient and the device.

  • What regulatory pathway was followed for this device’s approval, and what does that mean for clinicians?

    This pacemaker received FDA 510(k) clearance (K782146) under the Traditional review pathway, with the Cardiovascular (CV) Advisory Committee providing oversight. This means the device was deemed substantially equivalent to a legally marketed predicate device and is classified as a Class III medical device under FDA regulation 870.3610. Clinicians can rely on this approval as evidence of the device’s safety and effectiveness for its intended use, though ongoing postmarket surveillance applies.