Pacemaker Programmer 2030

by Cardiac Pacemakers, Inc.

510(k) K820230

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK820230 Date15 Mar 1982ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KRG
Device Class
Class III
Regulation
21 CFR Part 870.3700
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Pacemaker Programmer 2030 is a medical device classified as a Programmer, Pacemaker under FDA nomenclature (KRG product code). It is designed to interface with implanted pacemakers, enabling healthcare professionals to program, monitor, and adjust pacing parameters remotely. This device facilitates the customisation of cardiac rhythm therapy to meet individual patient needs, ensuring optimal cardiac function and patient management.

The Pacemaker Programmer 2030 is intended for use in clinical settings by trained medical personnel, such as cardiologists or electrophysiologists. Supplied as a reusable device, it requires no sterility guarantees but must adhere to strict electromagnetic compatibility and safety standards. Authorised under FDA 510(k) clearance (K820230) as substantially equivalent, it operates within the regulatory framework of 21 CFR 870.3700 for pacemaker programmers. Compatibility with multiple pacemaker models is supported via listed registration numbers.

Other devices from Cardiac Pacemakers, Inc.

See all devices from Cardiac Pacemakers, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of implanted pacemakers is the Pacemaker Programmer 2030 compatible with, and how do I verify compatibility for my specific model?

    The Pacemaker Programmer 2030 is designed to work with a wide range of implanted pacemaker models, as indicated by its compatibility with multiple OpenFDA registration numbers (e.g., 3011120183, 2017865, etc.). To verify compatibility for your specific pacemaker, check if its registration number appears in the listed OpenFDA registration_number field. This ensures the programmer can interface, program, and monitor your device’s pacing parameters. Always confirm with your manufacturer or a technical specialist if unsure.

  • Is the Pacemaker Programmer 2030 intended for single-use or repeated use in clinical settings, and what maintenance considerations apply?

    The Pacemaker Programmer 2030 is explicitly supplied as a reusable device, meaning it is designed for repeated use in clinical environments by trained professionals like cardiologists or electrophysiologists. Since it is not sterile, it must be cleaned and maintained according to electromagnetic compatibility (EMC) and safety standards—not clinical sterility protocols. Regular calibration and adherence to manufacturer guidelines are essential to ensure reliable performance and patient safety.

  • How do I confirm the regulatory status of the Pacemaker Programmer 2030, particularly regarding FDA clearance and compliance?

    The Pacemaker Programmer 2030 holds FDA 510(k) clearance (K820230) under the Traditional review pathway, classified as substantially equivalent (SESE) to a predicate device. It falls under 21 CFR 870.3700 for pacemaker programmers and is categorized under the KRG product code (Programmer, Pacemaker). For full details, refer to the FDA’s OpenFDA database using its k_number (K820230) or consult the manufacturer’s documentation for compliance and usage guidelines.

  • What clinical specialties or healthcare professionals are authorized to use the Pacemaker Programmer 2030, and why?

    The Pacemaker Programmer 2030 is intended for use by trained medical personnel in the cardiovascular specialty, specifically cardiologists or electrophysiologists. This restriction aligns with its advisory committee designation (CV) and the complexity of programming and monitoring implanted pacemakers, which require specialized training to ensure accurate adjustments and patient safety. Only authorized personnel should operate it.