Skip to content

Pacemaker, Prolith 23U Pulse Generator

by Edwards Pacemaker Systems

510(k) K780238

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK780238 Date15 Mar 1978ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Prolith 23U Pulse Generator is an implantable pacemaker pulse generator, classified as a Class III device. It features a power supply and electronic circuits designed to generate periodic electrical pulses, serving as a substitute for the heart’s intrinsic pacing system to address intermittent and continuous cardiac rhythm disorders. This device may operate in triggered, inhibited, or asynchronous modes to regulate heart function.

This device is intended for surgical implantation and is supplied sterile for single-use. It is regulated under FDA 510(k) clearance (K780238) and falls under the classification of an implantable pacemaker pulse-generator, adhering to regulatory standards for cardiovascular devices. Storage and handling must comply with sterile medical device protocols to ensure proper functionality and patient safety.

Other devices from Edwards Pacemaker Systems

See all devices from Edwards Pacemaker Systems →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of cardiac rhythm disorders can the Prolith 23U Pulse Generator address, and how does it regulate heart function?

    The Prolith 23U Pulse Generator is designed to address intermittent and continuous cardiac rhythm disorders by substituting for the heart’s natural pacing system. It generates periodic electrical pulses to maintain proper heart rhythm and can operate in triggered, inhibited, or asynchronous modes, allowing it to adapt to different clinical needs. This flexibility helps regulate heart function in patients with bradycardia or other rhythm abnormalities.

  • Is the Prolith 23U Pulse Generator intended for single-use or reusable applications, and what sterility precautions should be taken?

    The Prolith 23U is supplied sterile for single-use only, meaning it is not designed for reuse. To ensure patient safety and device functionality, it must be handled and stored according to sterile medical device protocols, including proper packaging integrity and environmental controls before implantation.

  • How is the Prolith 23U Pulse Generator regulated, and what does its FDA clearance status indicate?

    The Prolith 23U is regulated under FDA 510(k) clearance (K780238) and classified as a Class III device, indicating it carries higher risk and requires stringent oversight. The clearance status means it has been determined substantially equivalent to a legally marketed predicate device, ensuring it meets FDA safety and effectiveness requirements for implantable pacemaker pulse generators.

  • What storage and handling requirements should be followed for the Prolith 23U Pulse Generator to maintain its integrity?

    Since the Prolith 23U is sterile and single-use, it must be stored in its original packaging to preserve sterility. Handling should follow sterile medical device protocols, including protection from contamination, extreme temperatures, and physical damage. Always check expiration dates and ensure the device is not exposed to moisture or direct sunlight before use.