Skip to content

Padpro System Defibrillator Electrode Adapters

by Padpro, LLC

510(k) K003548

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK003548 Date4 Sep 2001ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MKJ
Device Class
Class III
Regulation
21 CFR Part 870.5310
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Padpro System Defibrillator Electrode Adapters are designed as interface components for automated external defibrillators (non-wearable). These adapters facilitate the connection between defibrillator pads and the device, ensuring proper electrical conductivity during resuscitation efforts. They are intended to enhance compatibility between different pad systems and defibrillator models, improving the reliability of shock delivery in emergency cardiac arrest scenarios.

These adapters are supplied as single-use, non-sterile components, intended for use in pre-hospital and clinical settings where defibrillation is required. They are classified as Class III medical devices under FDA regulations (870.5310) and have undergone a traditional 510(k) clearance process through the FDA’s Cardiovascular Advisory Committee. Storage should follow manufacturer guidelines to maintain functionality, and compatibility is verified with specific defibrillator models as listed in the registration data.

Other devices from Padpro, LLC

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these adapters reusable or single-use, and why does that matter in emergency settings?

    The Padpro System Defibrillator Electrode Adapters are designed as single-use components. This is critical in emergency settings because single-use devices minimize the risk of cross-contamination between patients, ensuring hygiene and safety during resuscitation efforts. Reusing medical devices in cardiac arrest scenarios could introduce pathogens or compromise electrical conductivity, potentially delaying or failing shock delivery when every second counts.

  • How do I know if these adapters will work with my defibrillator model, and what should I do if they’re not listed?

    Compatibility is verified with specific defibrillator models listed in the registration data (e.g., FEI numbers like 3026976873, 1218058, etc.). If your model isn’t listed, check the manufacturer’s documentation or contact Padpro, LLC directly (via Daniel Kamm at the provided address) for confirmation. Using incompatible adapters could result in poor electrical conductivity or failure to deliver a shock, risking patient safety during resuscitation.

  • Are these adapters sterile, and if not, how should they be handled to maintain safety in clinical or pre-hospital use?

    The adapters are non-sterile and intended for single-use in pre-hospital or clinical settings where defibrillation is required. Since they’re not sterile, proper handling includes avoiding contact with contaminated surfaces or fluids before use. Always follow manufacturer guidelines for storage and use, ensuring they remain clean and dry until deployment to prevent degradation or contamination that could interfere with functionality.

  • What storage instructions should I follow to keep these adapters functional until use?

    While exact storage instructions aren’t detailed in the data, the manufacturer recommends adhering to general guidelines for Class III medical devices to maintain functionality. Typically, this includes storing adapters in a cool, dry place, away from direct sunlight or extreme temperatures, and protecting them from physical damage. Avoid exposing them to moisture or chemicals, as these could compromise electrical conductivity or structural integrity before use.

  • Why are these adapters classified as Class III devices, and what does that mean for their use in healthcare settings?

    These adapters are classified as Class III under FDA regulations (870.5310) because they support life-sustaining or life-supporting functions—specifically, ensuring reliable shock delivery during defibrillation. Class III classification requires stringent oversight, including a traditional 510(k) clearance process reviewed by the FDA’s Cardiovascular Advisory Committee. This ensures they meet rigorous safety and performance standards before use in pre-hospital or clinical settings where cardiac arrest outcomes depend on accurate and timely defibrillation.