Panoview 884080
Ref 884080Model 10000201511
Panoview 884080 is a rigid endoscope telescope (EU MDD Class IIa; FDA Class II; FDA product code FJL, Resectoscope) made by Richard Wolf GmbH, registered in EUDAMED on 4 Sep 2026 (Basic UDI-DI B-04055207011300) and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 04055207011300), active as of 23 Oct 2026.
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04055207011300 04055207011300 | Date4 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04055207011300 | Date23 Sep 2016 | StatusListed |
Official records
- EUDAMED public site B-04055207011300
- AccessGUDID record 04055207011300
From the FDA record
- Device description
- STEREO-ENDOSCOPE 50° Ø 13.8MM SL 259MM rigid, with direct Stereo-and lateral documentation ocular lens, with irrigation channel, TL 410mm, rod lens system
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-04055207011300 registered 4 Sep 2026 Active
- FDA GUDID UDI-DI 04055207011300 listed 23 Sep 2016 Listed
Timeline
- Listed FDA GUDID 04055207011300
- Registered EUDAMED B-04055207011300
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Panoview
- Generic name
- Rigid endoscope telescope
- Device name
- Rigid TEM endosc. without work. channel
- Model / Ref / Catalog
- 884080, 10000201511
- Description
- STEREO-ENDOSCOPE 50° Ø 13.8MM SL 259MM rigid, with direct Stereo-and lateral documentation ocular lens, with irrigation channel, TL 410mm, rod lens system
- Primary DI / UDI-DI
- 04055207011300
- Basic UDI-DI
- B-04055207011300
- FDA product code
- FJL
- EMDN code
- Z12020605 Rectoscopes
- GMDN term
- Rigid endoscope telescope
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 876.1500
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Angle — 50 degreeOuter Diameter — 13.8 MillimeterLength — 259 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under LOWER GASTROINTESTINAL TRACT ENDOSCOPY INSTRUMENTS.
- EC-550L / by SONOSCAPE MEDICAL CORP.
- VERSA EC38-V10cM by PENTAX-Aohua Medical Technologies Co., Ltd.
- THD SLIDE 710004 by THD S.P.A.
- RESERVOIR TANK MAJ-1727 by Olympus Medical Systems Corporation
- BALLOON CONTROL UNIT OBCU by Olympus Medical Systems Corporation
- Single-Use Video Colonoscope RP-GI-C02B by Guangzhou Red Pine Medical Instrument Co.,Ltd.
- EC-550L/T by SONOSCAPE MEDICAL CORP.
- Single-Use Video Colonoscope RP-GI-C02A by Guangzhou Red Pine Medical Instrument Co.,Ltd.
- HOPKINS 24995BA by Karl Storz SE & CO. KG
- THD Slide One Fast (S) 800318 by THD S.P.A.