Identity

Trade Name
Park 1 FDA UDI
Generic Name
Ophthalmic refractometer, manual FDA UDI
Device Name
The PARK 1 combines three measuring functions in one unit. Auto-Refractometer An infrared light source projects measuring light onto the retina of the eye from where it is reflected back to the shutter location. Sensitive sensor chips, or CCD cameras now register the deviation of the reflected light from the shutter location. The deviation depends on the ametropia. From that, an integrated microcomputer calculates the ametropia in D, based on the sphere, cylinder and cylinder axis position. 1 Measuring ocular / Patient eyepiece 4 Chin rest 2 Keratometer ring 5 Marking for the eye height 3 Pachycam camera glass cover Keratometer To determine the curvature of the cornea, a reflected image of the cornea is captured by a camera sensor and is measured. The reflection of test marks and of a ring is used as the reflected image. This allows the central radii of the cornea to be determined. Pachymeter The pachymetry principle uses Scheimpflug images of the cornea, which are analysed by a built-in computer. 600 Absolute data points are evaluated with the Scheimpflug image. The measuring range lies on a 4 mm slit through the apex. The slit light illuminates a sectional plane from the front surface of the cornea to the back surface. The transparent cells of the cornea scatter the slit light such that the sectional plane appears as if it were self-luminous. This is captured at an angle of 45° through the pupil by a camera, whereby the image plane of the camera is also tilted 45° to the optical axis of the camera lens, in order to sharply focus the light-scattering cornea plane onto the image plane of the camera (Scheimpflug image). Thanks to this arrangement, sharp sectional images of the cornea can be attained. FDA UDI
Model / Reference
65000 FDA UDI
Description
The PARK 1 combines three measuring functions in one unit. Auto-Refractometer An infrared light source projects measuring light onto the retina of the eye from where it is reflected back to the shutter location. Sensitive sensor chips, or CCD cameras now register the deviation of the reflected light from the shutter location. The deviation depends on the ametropia. From that, an integrated microcomputer calculates the ametropia in D, based on the sphere, cylinder and cylinder axis position. 1 Measuring ocular / Patient eyepiece 4 Chin rest 2 Keratometer ring 5 Marking for the eye height 3 Pachycam camera glass cover Keratometer To determine the curvature of the cornea, a reflected image of the cornea is captured by a camera sensor and is measured. The reflection of test marks and of a ring is used as the reflected image. This allows the central radii of the cornea to be determined. Pachymeter The pachymetry principle uses Scheimpflug images of the cornea, which are analysed by a built-in computer. 600 Absolute data points are evaluated with the Scheimpflug image. The measuring range lies on a 4 mm slit through the apex. The slit light illuminates a sectional plane from the front surface of the cornea to the back surface. The transparent cells of the cornea scatter the slit light such that the sectional plane appears as if it were self-luminous. This is captured at an angle of 45° through the pupil by a camera, whereby the image plane of the camera is also tilted 45° to the optical axis of the camera lens, in order to sharply focus the light-scattering cornea plane onto the image plane of the camera (Scheimpflug image). Thanks to this arrangement, sharp sectional images of the cornea can be attained. FDA UDI

Identifiers

Primary DI / UDI-DI
04049584000217 FDA UDI
510(k) Number
K073508 FDA UDI
FDA Product Code
HLQ FDA UDI
HKO FDA UDI
MXK FDA UDI
GMDN Term
Ophthalmic refractometer, manual FDA UDI

Classification

Device Class
Class I FDA UDI
Regulation Number
886.1350 FDA UDI
886.1760 FDA UDI
886.1850 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

No

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

No

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

No

FDA UDI

Dimensions & Sizes

Size
Weight — 12 Kilogram FDA UDI
Depth — 530 Millimeter FDA UDI
Width — 538 Millimeter FDA UDI
Height — 265 Millimeter FDA UDI

Category: Ophthalmic refractometer, manual

Park 1 by OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung — Class I — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Ophthalmic refractometer, manual.

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI a40ea847-b377-47c1-978d-43101bcca848 36 fields · synced May 30, 2026