Identity
- Trade Name
- Pathfinder® CR System FDA UDI
- Generic Name
- Endoscope suction valve, single-use FDA UDI
- Device Name
- The Pathfinder® CR System is a disposable endoscopy fluid management system for the 14mm ID Pathfinder®Endoscope Overtube. It is designed to evacuate retained blood, free-floating blood clots, and fluid from the stomach in adult patients (22 years of age or older). It also provides access for endoscopic device passage and exchange. The suction adapter is attached to the Overtube and connected to a foot pedal to control suction on/off functionality. The foot pedal is connected to a suction source with vacuum regulator that provides a range between 200 to 375 mmHg (26.7 to 50.0 kPa). It is for use only by medically licensed and trained gastroenterologists located in hospitals, clinics, and doctor offices. FDA UDI
- Model / Reference
- GI 014CR-1 FDA UDI
- Description
- The Pathfinder® CR System is a disposable endoscopy fluid management system for the 14mm ID Pathfinder®Endoscope Overtube. It is designed to evacuate retained blood, free-floating blood clots, and fluid from the stomach in adult patients (22 years of age or older). It also provides access for endoscopic device passage and exchange. The suction adapter is attached to the Overtube and connected to a foot pedal to control suction on/off functionality. The foot pedal is connected to a suction source with vacuum regulator that provides a range between 200 to 375 mmHg (26.7 to 50.0 kPa). It is for use only by medically licensed and trained gastroenterologists located in hospitals, clinics, and doctor offices. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 00850006222322 FDA UDI
- 510(k) Number
- K240853 FDA UDI
- FDA Product Code
- FED FDA UDIFDS FDA UDI
- GMDN Term
- Endoscope suction valve, single-use FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 876.1500 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
Yes
FDA UDI
Single Use
Yes
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
No
FDA UDI
Category: Endoscope suction valve, single-use
Pathfinder® CR System by Neptune Medical — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Endoscope suction valve, single-use.
- CeroFrict — SML Med-Tech Solutions Limited · Class II
- CeroFrict — SML Med-Tech Solutions Limited · Class II
- CeroFrict — SML Med-Tech Solutions Limited · Class II
- CeroFrict — SML Med-Tech Solutions Limited · Class II
- CeroFrict — SML Med-Tech Solutions Limited · Class II
- FUJIFILM — FUJIFILM Corporation · Class II
- BioVac — US Endoscopy · Class II
- CeroFrict — SML Med-Tech Solutions Limited · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Neptune Medical
Sources (1)