Skip to content

Patient Reference Array Spine & Trauma

by Brainlab SE

Ref 55761B

Patient Reference Array Spine & Trauma (55761B) is an optical surgical tracking system spatial marker (EU MDR Class I; FDA Class II; FDA product code OLO, Orthopedic Stereotaxic Instrument) made by Brainlab SE, cleared under FDA 510(k) K262257 on 30 Sep 2026 (3 earlier submissions), registered in EUDAMED on 21 May 2024 (Basic UDI-DI 4056481PatRefArrayE8) and listed in FDA GUDID since 14 Nov 2024 (UDI-DI 04056481146238), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK262257 Date30 Sep 2026DecidedStatusActive
United StatesGUDID listing GUDID Number04056481146238 UDI-DI Date14 Nov 2024ListedStatusListed GUDID: in commercial distribution
European UnionCE/MDR EUDAMED Number4056481PatRefArrayE8 Basic UDI-DI 04056481146238UDI-DIDate21 May 2024RegisteredStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K262257 decided 30 Sep 2026 Active· +3 more in the status table
  • EUDAMED Basic UDI-DI 4056481PatRefArrayE8 registered 21 May 2024 Active
  • FDA GUDID UDI-DI 04056481146238 listed 14 Nov 2024 Listed

Recalls

3 recalls · FDA

    • Terminated Z-2925-2020 FDA Class II initiated 20 Aug 2020

    Holding force of the Positioning Arm can be reduced by prolonged non-use.

  • 2 recalls, same reason

    • Terminated Z-2793-2020 FDA Class II initiated 16 Jul 2020
    • Terminated Z-2792-2020 FDA Class II initiated 16 Jul 2020

    Incorrect manufacturer calibration

Timeline

9 dated events

  1. Cleared FDA 510(k) K183605
  2. Recall initiated FDA recalls Z-2793-2020
  3. Recall initiated FDA recalls Z-2792-2020
  4. Recall initiated FDA recalls Z-2925-2020
  5. Cleared FDA 510(k) K212245
  6. Registered EUDAMED 4056481PatRefArrayE8
  7. Listed FDA GUDID 04056481146238
  8. Cleared FDA 510(k) K252562
  9. Cleared FDA 510(k) K262257

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Optical surgical tracking system spatial marker, reusable
Model / reference
55761B
Primary DI / UDI-DI
04056481146238
Basic UDI-DI
4056481PatRefArrayE8
Direct marketing DI
04056481146238
FDA product code
OLO
EMDN code
Z12011480 Surgical navigation instruments - hardware accessories
GMDN term
Optical surgical tracking system spatial marker, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
882.4560
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000006183

Similar devices in this category

Other devices filed under SURGICAL NAVIGATION INSTRUMENTS - HARDWARE ACCESSORIES.

Other devices from Brainlab SE

See all devices from Brainlab SE →

Properties

  • Sterilise before use
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (21, all answered No)