Skip to content

PCA Solid Back Acetabular Shell

by Howmedica Corp.

510(k) K930833

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK930833 Date22 Feb 1994ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Pca(R) Solid Back Acetabula Shell
510(k) Number
FDA Product Code
JDL
Device Class
Class III
Regulation
21 CFR Part 888.3320
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The PCA Solid Back Acetabular Shell is a semi-constrained metal cemented acetabular component for the hip, designed to provide structural support and stability in total hip arthroplasty. This device is intended to replace the natural acetabulum, facilitating proper articulation with the femoral component to restore hip function and mobility.

This acetabular shell is supplied as a reusable surgical implant and is intended for use in orthopedic procedures within a sterile operating environment. It is classified as a Class III device under FDA regulations (888.3320) and was granted a 510(k) clearance in 1994. The device is manufactured by Howmedica Corp. and is identified by the product code JDL, with multiple registration numbers associated with its variants.

Other devices from Howmedica Corp.

See all devices from Howmedica Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of hip procedures is the PCA Solid Back Acetabular Shell designed for, and how does it differ from other acetabular components?

    The PCA Solid Back Acetabular Shell is specifically designed for total hip arthroplasty (replacement surgery) to replace the natural acetabulum. It is a semi-constrained, metal cemented acetabular component, meaning it relies on bone cement for fixation and offers moderate stability to the femoral head. This design helps restore hip function and mobility by ensuring proper articulation with the femoral component. Unlike unconstrained shells, it provides additional stability for patients who may need it, while still allowing for natural movement.

  • Is the PCA Solid Back Acetabular Shell intended for single-use or can it be reused in multiple procedures?

    The PCA Solid Back Acetabular Shell is explicitly described as a reusable surgical implant. It is intended for use in orthopedic procedures within a sterile operating environment, meaning it can be sterilized and used in multiple surgeries, provided proper sterilization protocols are followed.

  • What are the key features of the PCA Solid Back Acetabular Shell that make it suitable for cemented fixation?

    The PCA Solid Back Acetabular Shell is designed as a cemented acetabular component, meaning it relies on bone cement to bond directly to the patient’s pelvic bone. This feature provides a stable foundation for the femoral head to articulate with, ensuring long-term fixation and durability in total hip arthroplasty. The solid back design enhances structural support, reducing the risk of loosening or displacement over time.

  • How many variants or sizes of the PCA Solid Back Acetabular Shell are available, and how are they identified?

    The PCA Solid Back Acetabular Shell comes in multiple variants, each identified by unique registration numbers (e.g., 8043792, 3020282716, etc.) and associated FEI numbers. These variants likely correspond to different sizes or configurations to accommodate varying patient anatomies. The product code JDL categorizes this device under FDA regulations, and the manufacturer, Howmedica Corp., would provide specific sizing details for surgical planning.

  • What storage and handling considerations should be taken into account for the PCA Solid Back Acetabular Shell?

    Since the PCA Solid Back Acetabular Shell is reusable, it must be stored in a clean, dry environment to prevent contamination. Before use, it must undergo proper sterilization (e.g., autoclaving or ethylene oxide) to ensure sterility in the operating room. Additionally, it should be handled with sterile instruments and packaging to maintain its integrity and prevent cross-contamination between procedures.