# Pediatric-Pak Pad-Pak-02

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/pediatric-pak-pad-pak-02-e06bc86c>
- Manufacturer: [Heartsine Technologies Ltd](https://devicerts.com/manufacturers/heartsine-technologies-ltd) (Northern Ireland)
- Device class: Class IIb (EU MDR); Class III (US FDA)
- FDA product code: MKJ
- EMDN: Z12030585 DEFIBRILLATORS - CONSUMABLES
- GMDN: Non-rechargeable public semi-automated external defibrillation electrode, paediatric (47912)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 08858251001696TG · UDI-DI 05060167120473 · registered 2026-09-09 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 05060167120473 · listed 2020-08-20 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA PMA · United States · P160008 · decision 2017-01-12 · decision APPR · status: Active · from GUDID

## Recalls

- Z-3120-2026 · Class II · ongoing · initiated 2026-07-27: Due to a damaged (over stretched) membrane tail that causes an intermittent fault.
- Z-3270-2026 · Class III · ongoing · initiated 2026-07-27: Products were distributed without the required Maintenance Supplement, which describes an extra check every 3 months in addition to the monthly check.
- Z-0288-2026 · Class II · ongoing · initiated 2025-09-18: Due to customer complaints, defibrillator pads may contain damage pins that disrupt the mechanical fit and electrical contact.
- Z-2174-2025 · Class II · ongoing · initiated 2025-06-30: Due to a component manufacturing issue, Automated External Defibrillator may not function properly (deliver shocks)
- Z-2143-2023 · Class II · ongoing · initiated 2023-04-26: Single use battery and electrode cartridge may be rendered inoperable due to depleted battery cells which could prevent the defibrillator from analyzing patient condition or delivering therapy correctly.
- Z-1217-2023 · Class II · ongoing · initiated 2023-02-01: Automated external defibrillators were potentially distributed with the incorrect language configuration, which can lead to a delay in therapy or no therapy.
- Z-0745-2022 · Class III · terminated · initiated 2022-01-13: Semi-automatic defibrillators shipped out by Stryker without battery and electrode packs.

## Identity

- Trade name: Pediatric-Pak [EUDAMED, FDA GUDID (AccessGUDID)]
- Generic name: Non-rechargeable public semi-automated external defibrillation electrode, paediatric [FDA GUDID (AccessGUDID)]
- Device name: Combined Pad-Pak & Pediatric-Pak [EUDAMED]
- Model / Ref / Catalog: Pad-Pak-02 [EUDAMED, FDA GUDID (AccessGUDID)]; 08858251001696TG [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 05060167120473 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 08858251001696TG [EUDAMED]
- Direct marketing DI: 05060167120473 [EUDAMED]
- PMA number: P160008 [FDA GUDID (AccessGUDID)]
- FDA product code: MKJ [FDA GUDID (AccessGUDID)]
- EMDN code: Z12030585 [EUDAMED]
- GMDN term: Non-rechargeable public semi-automated external defibrillation electrode, paediatric (47912) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class III [FDA GUDID (AccessGUDID)]
- Regulation number: 870.5310 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Northern Ireland [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Pediatric-Pak Pad-Pak-02, Heartsine Technologies Ltd. deviCERTS medical device catalogue. https://devicerts.com/devices/pediatric-pak-pad-pak-02-e06bc86c (data as of 2026-11-19).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-25
- Statuses computed as of: 2026-11-19
- JSON: <https://devicerts.com/devices/pediatric-pak-pad-pak-02-e06bc86c.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/pediatric-pak-pad-pak-02-e06bc86c
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.