Skip to content

Pentacam HR

by OCULUS Optikgeräte GmbH

Ref 70900

Pentacam HR (70900) is a corneal topography system (EU MDR Class IIa; FDA Class II; FDA product code MXK, Device,Analysis,Anterior Segment) made by OCULUS Optikgeräte GmbH, registered in EUDAMED on 10 Feb 2026 (Basic UDI-DI 40495846BL), cleared under FDA 510(k) K030719 on 16 Sep 2003 and listed in FDA GUDID since 1 Sep 2016 (UDI-DI 04049584000026), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K030719

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number40495846BL Basic UDI-DI 04049584000026UDI-DIDate10 Feb 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04049584000026 UDI-DI Date1 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK030719 Date16 Sep 2003DecidedStatusActive

Official records

From the FDA record

Device description
The Pentacam Scheimpflug Camera is a non-invasive, diagnostic system created to take photographs of the anterior segment of the eye, table mounted and AC powered. The system is based on the Scheimpflug Principle for Slit Image photography. The device consists of a measurement unit, power supply and a CPU. The measuring system uses blue light (UV-free) given to a slit to illuminate the eye, and a CCD-Camera for photography. The measuring system offers the possibility of automatically rotation to get photographs of every part of the eye. The system calculates from the photos a 3D-model1 of the eye
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 40495846BL registered 10 Feb 2026 Active
  • FDA 510(k) K030719 decided 16 Sep 2003 Active
  • FDA GUDID UDI-DI 04049584000026 listed 1 Sep 2016 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1674-2022 FDA Class II initiated 8 Jul 2022 UDI-DI 04049584000026 listed

    Due to a software issue, IOL calculator printout often does not accurately reflect the alignment axis and incision position when planning toric IOLs

Timeline

4 dated events

  1. Cleared FDA 510(k) K030719
  2. Listed FDA GUDID 04049584000026
  3. Recall initiated FDA recalls Z-1674-2022
  4. Registered EUDAMED 40495846BL

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Corneal topography system
Model / reference
70900
Primary DI / UDI-DI
04049584000026
Basic UDI-DI
40495846BL
510(k) Number
FDA product code
MXK
EMDN code
Z12120123 Computerised corneal topographs
GMDN term
Corneal topography system
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
886.1850
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Size
Height — 535 Millimeter
Depth — 360 Millimeter
Width — 280 Millimeter
Weight — 11 Kilogram

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000012227

Similar devices in this category

Other devices filed under COMPUTERISED CORNEAL TOPOGRAPHS.

Other devices from OCULUS Optikgeräte GmbH

See all devices from OCULUS Optikgeräte GmbH →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)