Skip to content

Percussionaire A50094-D

by Percussionaire Corporation

Percussionaire A50094-D is a ventilator breathing circuit (FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Percussionaire Corporation, cleared under FDA 510(k) K905235 on 3 May 1991 and listed in FDA GUDID since 21 Oct 2015 (UDI-DI 00849436000259), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

510(k) K905235

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00849436000259 UDI-DI Date21 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK905235 Date3 May 1991DecidedStatusActive

Official records

From the FDA record

Device description
Phasitron Kit, VDR, Single Patient
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K905235 decided 3 May 1991 Active
  • FDA GUDID UDI-DI 00849436000259 listed 21 Oct 2015 Listed

Recalls

3 recalls · 2 ongoing · FDA

    • Ongoing Z-0960-2025 FDA Class I initiated 23 Dec 2024

    Due to internal venturi component getting transiently stuck in the forward position within the breathing circuit and may cause a reduction of amplitude and volume of ventilation.

    • Ongoing Z-0693-2024 FDA Class I initiated 28 Mar 2023

    Breathing circuit reservoir bag may be assembled at the wrong attachment point, which will result in less than optimal therapy.

    • Completed Z-0259-2024 FDA Class II initiated 14 Sep 2020

    Note this recall occurred in 2020 and 2021. Reports of screen freeze on visual displays of waveform analyzers that are paired with ventilators. Subsequently, waveform analyzers were serviced to install PAL microprocessor chips and firmware.

Timeline

5 dated events

  1. Cleared FDA 510(k) K905235
  2. Listed FDA GUDID 00849436000259
  3. Recall initiated FDA recalls Z-0259-2024
  4. Recall initiated FDA recalls Z-0693-2024
  5. Recall initiated FDA recalls Z-0960-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Percussionaire
Generic name
Ventilator breathing circuit, single-use
Model / Ref / Catalog
A50094-D
Primary DI / UDI-DI
00849436000259
510(k) Number
FDA product code
CBK
GMDN term
Ventilator breathing circuit, single-use
Device class
Class II
Regulation number
868.5895
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Ventilator breathing circuit, single-use.

Other devices from Percussionaire Corporation

See all devices from Percussionaire Corporation →

Properties

  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (10, all answered No)