Philips Avalon Fetal Monitors FM20 and FM30
by Philips Medizinsysteme Boeblingen GmbH, Cardiac AN
510(k) K071800
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK071800 | Date27 Sep 2007 | StatusActive |
Recalls
-
- Terminated Z-0549-2010
- Terminated Z-0550-2010
Potential for inaccurate ultra-sound derived fetal heart rate readings in Philips Avalon Fetal Monitors. Although the types of inaccuracies described in these complaints reflect known limitations inherent to ultrasound fetal heart rate monitoring, the frequency of such complaints is greater for these devices than for the previous generation Philips Series 50 fetal monitors. Clinical decisions bas
-
- Terminated Z-1478-2009
- Terminated Z-1479-2009
Interruption of power-up/boot sequence may cause the paper scale and recorder speed settings of the monitor to revert to factory default may lead to misinterpretation of the fetal trace by the user and to potential incorrect clinical decisions
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- HGM
- Device Class
- Class II
- Regulation
- 21 CFR Part 884.2740
- Advisory Committee
- Obstetrics/Gynecology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 27 Sep 2026
The Philips Avalon Fetal Monitors FM20 and FM30 are systems for monitoring perinatal parameters, designed for noninvasive monitoring of pregnant women during antepartum testing and labor and delivery. They measure fetal and maternal heart rates separately and incorporate automated coincidence detection (cross-channel verification) using Smart Pulse technology to enhance diagnostic confidence.
These devices are supplied as reusable monitors intended for use in clinical settings such as antepartum and intrapartum settings. They connect to the IntelliSpace Perinatal system to support the continuum of care from antepartum visits through delivery, postpartum, and newborn nursery follow-up. The device has received FDA 510(k) clearance under K071800 and is classified as a Class II medical device under regulation number 884.2740.
Other devices from Philips Medizinsysteme Boeblingen GmbH, Cardiac AN
See all devices from Philips Medizinsysteme Boeblingen GmbH, Cardiac AN →
Questions
AI-generated answers, 27 Sep 2026
What is the Philips Avalon FM20 and FM30 fetal monitor used for?
The Philips Avalon FM20 and FM30 are designed for noninvasive monitoring of pregnant women during antepartum testing and labor and delivery, measuring fetal and maternal heart rates separately using Smart Pulse technology for automated coincidence detection to enhance diagnostic confidence.
Is the Philips Avalon FM20 and FM30 fetal monitor reusable or single-use?
The Philips Avalon FM20 and FM30 are supplied as reusable monitors intended for use in clinical settings such as antepartum and intrapartum environments, meaning they are designed for repeated use after proper cleaning and disinfection between patients.
How does the Philips Avalon FM20 and FM30 connect to other systems for perinatal care?
The Philips Avalon FM20 and FM30 connect to the IntelliSpace Perinatal system to support the continuum of care from antepartum visits through delivery, postpartum, and newborn nursery follow-up, enabling integrated data management across care stages.