# Phosphoplastin RL

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/phosphoplastin-rl-gjs>
- Manufacturer: [R 2 Diagnostics, Inc.](https://devicerts.com/manufacturers/r-2-diagnostics-inc) (FDA registration: United States)
- Name in the registry: PHOSPHOPLASTIN RL
- Device class: IVD General (EU IVDD); Class II (US FDA)
- FDA product code: GJS
- EMDN: W0103020101 PROTHROMBIN TIME ( QUICK TEST )
- GMDN: Prothrombin time (PT) IVD, reagent (55986)

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

Phosphoplastin RL is a liquid thromboplastin reagent used in the one-stage prothrombin time (PT) test, a critical in vitro diagnostic assay for assessing coagulation function. It is designed for extrinsic factor assays and therapeutic monitoring of anticoagulant drugs such as Warfarin, enabling clinicians to evaluate coagulopathies and monitor hemostasis.

The device is supplied as a liquid reagent intended for single-use in clinical coagulation laboratories. It is classified as a Class II medical device under FDA regulations (864.7750) and has received both FDA 510(k) clearance and In Vitro Diagnostic Device (IVDD) authorization. Storage and handling conditions are not specified in the provided data, but standard laboratory practices for sensitive reagents should be followed.

## Registrations and authorizations

- **EUDAMED** · CE/IVDD · European Union · Basic UDI-DI B-10859394006030 · registered 2026-05-19 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 10859394006023 · listed 2016-11-15 · status: Listed (GUDID: in commercial distribution)
- **510(k)** · FDA 510(k) · United States · K040296 · decision 2004-05-24 · decision SESE · status: Active

## Recalls

No recall on record.

## Identity

- Generic name: Prothrombin time (PT) IVD, reagent [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 11-305 [EUDAMED, FDA GUDID (AccessGUDID)]; 11-310 [EUDAMED, FDA GUDID (AccessGUDID)]
- Description: PT reagent 10 x 5 ml [FDA GUDID (AccessGUDID)]; PT reagent 10 x 10 ml [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 10859394006023 [EUDAMED, FDA GUDID (AccessGUDID)]; 10859394006030 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-10859394006030 [EUDAMED]; B-10859394006023 [EUDAMED]
- 510(k) Number: K040296 [FDA 510(k), FDA GUDID (AccessGUDID)]
- FDA product code: GJS [FDA 510(k), FDA GUDID (AccessGUDID)]
- EMDN code: W0103020101 [EUDAMED]
- GMDN term: Prothrombin time (PT) IVD, reagent (55986) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IVD General [EUDAMED]; Class II [FDA 510(k), FDA GUDID (AccessGUDID)]
- Regulation: 21 CFR Part 864.7750 [FDA 510(k), FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]
- EU market of registration: Italy [EUDAMED]
- Advisory committee: Hematology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Single use: Yes [FDA GUDID (AccessGUDID)]
- Contains animal tissues or cells: No [EUDAMED]; Yes [EUDAMED]
- Reagent: Yes [EUDAMED]
- IVD kit: Yes [EUDAMED]
- Professional testing: Yes [EUDAMED]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Contains human tissues or cells: No [EUDAMED]
- Contains substances of microbial origin: No [EUDAMED]
- Self-testing: No [EUDAMED]
- Near-patient testing: No [EUDAMED]
- Companion diagnostics: No [EUDAMED]
- IVD instrument: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Phosphoplastin RL, R 2 Diagnostics, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/phosphoplastin-rl-gjs (data as of 2026-11-22).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed)
- Registry records last synced: 2026-11-08
- Statuses computed as of: 2026-11-22
- JSON: <https://devicerts.com/devices/phosphoplastin-rl-gjs.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/phosphoplastin-rl-gjs
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.