Pipeline Flex Embolization Device and Pipeline Flex Embolization Device with Shield Technology

by Micro Therapeutics, Inc. d/b/a ev3 Neurovascular

PMA P100018

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

PMA P100018↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPPR Approved NumberP100018 Date6 Apr 2011ApprovedStatusActive

Recalls

12 recalls · 4 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1245-2025 FDA Class I initiated 30 Jan 2025
    • Ongoing Z-1246-2025 FDA Class I initiated 30 Jan 2025

    Use of embolization device with diameters greater-than-or-equal-to 4mm may lead to incomplete wall apposition and/or braid deformation (fish-mouthing/braid narrowing/braid collapse) noted during procedure and post-procedure, typically noted at 6-12 month imaging follow-up, potentially can lead to thrombosis and/or serious adverse events. Higher risk in females less-than-or-equal-to 45 years of age

  • 2 recalls, same reason

    • Ongoing Z-2403-2021 FDA Class I initiated 13 Jul 2021
    • Ongoing Z-2402-2021 FDA Class I initiated 13 Jul 2021

    Due to potential push wire fractures in the delivery system during use. The issue presents as a fracture in the spiral cut area of the Hypotube.

    • Terminated Z-1527-2020 FDA Class I initiated 14 Feb 2020

    Embolization device delivery system may fracture at the distal section during device implantation. A weakened bond may result in unintended separation, where the distal portion of the device delivery system remains in the patient. If a Pipeline Flex embolization device has already been implanted successfully, there is no increased risk to patients due to this issue.

  • 4 recalls, same reason

    • Terminated Z-0309-2017 FDA Class I initiated 5 Oct 2016 on shared PMA P100018
    • Terminated Z-0308-2017 FDA Class I initiated 5 Oct 2016 on shared PMA P100018
    • Terminated Z-0307-2017 FDA Class I initiated 5 Oct 2016
    • Terminated Z-0310-2017 FDA Class I initiated 5 Oct 2016 on shared PMA P100018

    Delamination and detachment of the PTFE (polytetrafluoroethylene) coating material may lead to PTFE coating in the blood stream.

    • Terminated Z-0120-2016 FDA Class II initiated 4 Sep 2015

    The firm is recalling Pipeline and Pipeline Flex Embolization Devices from U.S. since the devices were shipped with an EU version of the Instructions for Use.

    • Terminated Z-1453-2014 FDA Class I initiated 1 Apr 2014 on shared PMA P100018

    Potential for the PTFE (polytetrafluoroethylene) coating to delaminate and detach from the delivery wire.

    • Terminated Z-2045-2013 FDA Class II initiated 19 Jul 2013

    Covidien Neurovascular has initiated the recall of several lots of Pipeline Embolization Device (PED) because the Instructions For Use (IFU) do not include the following contraindication: Patients in whom a pre-existing stent is in place in the parent artery at the target aneurysm location. Additionally, the designation of aspirin and clopidogrel was missing from the following contraindication "

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Trade Name
Pipeline Embolization Device
Generic Name
Intracranial aneurysm flow diverter
PMA Number
FDA Product Code
OUT
Device Class
Class III
Advisory Committee
Neurology
FDA Decision
APPR Approved

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Pipeline Flex Embolization Device is an intracranial aneurysm flow diverter, classified as a Device Class 3 medical device. It is designed to promote aneurysm occlusion by diverting blood flow away from the aneurysm sac, thereby reducing pressure and facilitating natural healing processes in wide-necked intracranial aneurysms located in the internal carotid artery from the petrous to the superior hypophyseal segments.

This device is supplied as a single-use, endovascular implant and is intended for use in neurovascular procedures under radiographic guidance. It is approved for adults aged 22 and above and requires sterile handling, with specific sizing and deployment considerations based on anatomical requirements. The device is regulated under an FDA Premarket Approval (PMA) process, with the PMA number P100018, and is categorized under the product code OUT in the regulatory database.

Other devices from Micro Therapeutics, Inc. d/b/a ev3 Neurovascular

See all devices from Micro Therapeutics, Inc. d/b/a ev3 Neurovascular →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Pipeline Flex Embolization Device used for in clinical practice?

    The Pipeline Flex Embolization Device is designed to treat large or giant wide-necked intracranial aneurysms in adults aged 22 and above. It works by diverting blood flow away from the aneurysm sac in the internal carotid artery, reducing pressure and promoting natural healing. This is specifically for aneurysms located between the petrous and superior hypophyseal segments.

  • Is the Pipeline Flex Embolization Device intended for reuse, or is it single-use?

    The Pipeline Flex Embolization Device is explicitly supplied as a single-use, endovascular implant. It requires sterile handling and cannot be reused after deployment, as is standard for most intracranial implants.

  • What regulatory pathway does the Pipeline Flex Embolization Device follow, and how can I verify its approval?

    The device follows the FDA Premarket Approval (PMA) pathway, with the PMA number **P100018**. It was approved for its intended use in intracranial aneurysm treatment after undergoing a rigorous review process, including an expedited review. The approval notice was published in the Federal Register on **2011-04-20**.

  • Are there different sizes or models available for the Pipeline Flex Embolization Device?

    Yes, the Pipeline Flex Embolization Device comes in multiple sizes, as indicated by the **FEI numbers** (e.g., 3010079067, 3007628272, etc.) listed in the regulatory records. These variations allow for customization based on anatomical requirements during deployment in the internal carotid artery.

  • How should the Pipeline Flex Embolization Device be stored before use?

    Since it is a sterile, single-use device, storage conditions must maintain sterility until deployment. While specific storage instructions are not detailed here, typical best practices for endovascular implants—such as keeping it in a sealed, sterile packaging at room temperature away from direct sunlight—should be followed. Always refer to the manufacturer’s provided instructions for precise storage guidelines.