Platinum P4H
Platinum P4H (SLP4H) is a musculoskeletal/physical therapy laser (FDA Class II; FDA product code ILY, Lamp, Infrared, Therapeutic Heating) made by Summus Medical Laser, listed in FDA GUDID since 27 Oct 2020 (UDI-DI B679SLP4H0), registry data as of 23 Oct 2026.
Listed
Valid until
Not applicable
FDA recalls
Not checked
Documents
None
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | NumberB679SLP4H0 | Date27 Oct 2020 | StatusListed |
From the FDA record
- Device description
- Light weight (~2.5 Kg.) and portable therapeutic medical laser device (measuring ~258.65mm x 238.43m x 88.86mm) disc shaped, indicated for temporary relief of minor muscle and joint pain, stiffness, minor arthritis pain, muscle spasm, temporary increase in local blood circulation, and temporary relaxation of muscles by means of topical elevated tissue temperature from infrared spectral emissions. The noninvasive laser treatments (Continuous Wave - CW power 28W and Intense Super Pulse - ISP power 30W) are in the form of non-ionizing radiation in which the invisible light wave doses (810nm +/- 10nm, 915nm +/- 10nm, 980nm +/- 10nm) and visible light wave aiming beam (650nm +/- 20nm) are not cumulative and do not create changes in cellular DNA. The presence of a temperature gradient generates an increased local blood circulation through the tissue to reduce inflammation and pain and to enhance the rate of tissue repair. The laser energy increases circulation, drawing water, oxygen, and nutrients to the target area. The increase in circulation provides a healing environment that reduces inflammation, swelling, muscle spasm, stiffness, and pain. The increased circulation of blood speeds up the process of respiratory cellular activity by stimulating an increase in hemoglobin and nutrients at the target cell and a decrease in cellular carbon dioxide and lactic acid waste. The laser light therapy promotes the transport of nutrients across the cell membrane to aid in the natural repair mechanism of the target cells by stimulating an increase in production of Adenosine Triphosphate (ATP) energy in the cell. The increase in ATP energy and the decrease in waste enhances cellular function and tissue repair.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — GUDID listing Listed
Specification
- Trade name
- Platinum
- Generic name
- Musculoskeletal/physical therapy laser, professional
- Model / Ref / Catalog
- P4H, SLP4H
- Primary DI / UDI-DI
- B679SLP4H0
- FDA product code
- ILY
- GMDN term
- Musculoskeletal/physical therapy laser, professional
- Device class
- Class II
- Regulation number
- 890.5500
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code ILY (Lamp, Infrared, Therapeutic Heating).
- FIRARD II/ TDP LAMP by Helio Medical Supplies, Inc.
- OLYMPIC WARM-LAMP by Olympic Medical Corp.
- LUMIX 3 PLUS AND LUMIX 3 ULTRA SYSTEM by Texas Applied Biomedical Services
- ACUMED LASER, MODEL 1000 by Laser Thera, LLC
- SPINAL PAD by Bioscan, Inc.
- NovoTHOR XL 3.0 by THOR PHOTOMEDICINE INC.
- WEBERNEEDLE BASIC LASER by Weber Medical GmbH
- Laserpen Practise and Expert, Handylaser Sprint, Handylaser Trion, Physiolaser Olympic, Polylaser by Reimers & Janssen GmbH
- WS FREQUENCY SPECTRUM EFFECT PHYSIATRICS APPARATUS by C A I INDUSTRIES CORP
- LUMANOSITY CELEBRITY, MODEL 204 by Lumanosity, Inc.