Plum 1968528

by ICU Medical, Inc.

Plum 1968528 is a Class II device made by ICU Medical, Inc., cleared under FDA 510(k) K141789 on 16 Jan 2015 and listed in FDA GUDID since 1 Sep 2016 (UDI-DI 10887787008897), active as of 23 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

4 ongoing

Recall on shared 510(k) K141789; other models may be affected

Documents

510(k) K141789

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10887787008897 UDI-DI Date1 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK141789 Date16 Jan 2015DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K141789 decided 16 Jan 2015 Active
  • FDA GUDID UDI-DI 10887787008897 listed 1 Sep 2016 Listed

Recalls

11 recalls · 4 ongoing · FDA

    • Ongoing Z-3162-2026 FDA Class II initiated 12 May 2026 on shared 510(k) K141789

    Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall. The presence of discoloration and particulate matter in the fluid path has not been ruled out.

  • 2 recalls, same reason

    • Ongoing Z-2447-2024 FDA Class I initiated 7 May 2024 on shared 510(k) K141789
    • Ongoing Z-1565-2023 FDA Class I initiated 22 Mar 2023 on shared 510(k) K141789

    Due to a manufacturing defect from the battery supplier, affected batteries may experience a loss of capacity earlier in the battery lifecycle than expected and overall battery runtime may decrease earlier in the battery lifecycle than expected.

    • Ongoing Z-2430-2023 FDA Class II initiated 13 Jul 2023 on shared 510(k) K141789

    Due to a manufacturing defect of a supplier provided component, there is a potential that the audible signal for an alarm may not sound under certain conditions.

  • 3 recalls, same reason

    • Terminated Z-0127-2020 FDA Class II initiated 29 Jul 2019 on shared 510(k) K141789
    • Terminated Z-0128-2020 FDA Class II initiated 29 Jul 2019 on shared 510(k) K141789
    • Terminated Z-0145-2020 FDA Class II initiated 29 Jul 2019 on shared 510(k) K141789

    Potential for fluid leakage out of air vents on inline filters on Plum and Sapphire micropore infusion sets.

    • Terminated Z-3031-2017 FDA Class II initiated 15 Jun 2017 on shared 510(k) K141789

    Potential for the Connectivity Engine Module of the affected unit to disengage from the main chassis, causing the unit to shut down without an alarm notification. This would delay initiation of therapy or interrupt an infusion.

    • Terminated Z-1682-2017 FDA Class II initiated 30 Dec 2016 on shared 510(k) K141789

    Depleted Battery alarm shows instead of Replace Battery. On battery power, ongoing therapy stops, alarms show and sound, pump shuts down after 3 minutes. On AC power, the pump reboots (takes about 25 seconds). Therapy can resume. AC power interruption of 3-7 seconds prompts an incorrect E323 alarm, ongoing therapy stop, and pump reboot. Longer power loss results in battery power operation.

  • 2 recalls, same reason

    • Terminated Z-1832-2016 FDA Class II initiated 25 Mar 2016 on shared 510(k) K141789
    • Terminated Z-1833-2016 FDA Class II initiated 25 Mar 2016 on shared 510(k) K141789

    Firm's investigation determined that the Proximal Occlusion Alarms observed in the field were attributed to the mechanism calibration process being performed with an out of specification metal cassette, resulting in an offset in proximal pressure.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Listed FDA GUDID 10887787008897
  2. Recall initiated FDA recalls Z-1682-2017
  3. Recall initiated FDA recalls Z-3031-2017
  4. Recall initiated FDA recalls Z-0127-2020
  5. Recall initiated FDA recalls Z-0128-2020
  6. Recall initiated FDA recalls Z-0145-2020
  7. Recall initiated FDA recalls Z-1565-2023
  8. Recall initiated FDA recalls Z-2430-2023
  9. Recall initiated FDA recalls Z-2447-2024
  10. Recall initiated FDA recalls Z-3162-2026

3 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Plum
Generic name
Bedside infusion pump, single-channel
Model / Ref / Catalog
1968528
Primary DI / UDI-DI
10887787008897
510(k) Number
FDA product code
FPA
GMDN term
Bedside infusion pump, single-channel
Device class
Class II
Regulation number
880.5440
GUDID distribution status
In Commercial Distribution
Size
Length — 136 Inch

Similar devices

Other devices filed under FDA product code FPA (Set, administration, intravascular).

Other devices from ICU Medical, Inc.

See all devices from ICU Medical, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)