Pointe Scientific HH945-480 is a medical device (FDA Class I; FDA product code LBR, Ldl & Vldl Precipitation, Hdl) made by Horiba Instruments Incorporated, cleared under FDA 510(k) K992002 on 5 Aug 1999 and listed in FDA GUDID since 31 Aug 2016 (UDI-DI 00811727012913), active as of 24 Oct 2026. 7 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

13 closed

Documents

510(k) K992002

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00811727012913 UDI-DI Date31 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK992002 Date5 Aug 1999DecidedStatusActive

Official records

From the FDA record

Device description
HDL reagent for the quantitative determination high-density lipoprotein cholesterol in human serum or plasma. For in vitro diagnostic use only. 6 x 60ml, 6 x 20ml
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K992002 decided 5 Aug 1999 Active
  • FDA GUDID UDI-DI 00811727012913 listed 31 Aug 2016 Listed

Recalls

13 recalls · FDA

    • Terminated Z-0389-2019 FDA Class III initiated 10 Aug 2018

    Vials of the autoHDL/LDL Calibrator were shipped without a vial label.

    • Terminated Z-2764-2015 FDA Class III initiated 13 Mar 2015

    Crystals may be observed in the R1 reagent. Crystals may be a result of the reagent being frozen during transport. The crystals do not impact product performance.

  • 2 recalls, same reason

    • Terminated Z-1200-2009 FDA Unclassified (pre-2012) initiated 29 Jan 2009
    • Terminated Z-1201-2009 FDA Unclassified (pre-2012) initiated 29 Jan 2009

    The R1 reagent has microbial contamination.

  • 9 recalls, same reason

    • Terminated Z-0074-2007 FDA Unclassified (pre-2012) initiated 18 Sep 2006
    • Terminated Z-0075-2007 FDA Unclassified (pre-2012) initiated 18 Sep 2006
    • Terminated Z-0076-2007 FDA Unclassified (pre-2012) initiated 18 Sep 2006
    • Terminated Z-1457-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002
    • Terminated Z-1458-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002
    • Terminated Z-1454-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002
    • Terminated Z-1459-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002
    • Terminated Z-1456-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002
    • Terminated Z-1455-06 FDA Unclassified (pre-2012) initiated 12 Jun 2006 on shared 510(k) K992002

    Unexpected changes in QC and proficiency results due to QC and proficiency material matrix.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

15 dated events

  1. Recall initiated FDA recalls Z-1456-06
  2. Recall initiated FDA recalls Z-1455-06
  3. Recall initiated FDA recalls Z-0074-2007
  4. Recall initiated FDA recalls Z-0075-2007
  5. Recall initiated FDA recalls Z-0076-2007
  6. Recall initiated FDA recalls Z-1200-2009
  7. Recall initiated FDA recalls Z-1201-2009
  8. Recall initiated FDA recalls Z-2764-2015
  9. Listed FDA GUDID 00811727012913
  10. Recall initiated FDA recalls Z-0389-2019

5 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Pointe Scientific
Generic name
High density lipoprotein (HDL) cholesterol IVD, reagent
Model / Ref / Catalog
HH945-480
Primary DI / UDI-DI
00811727012913
510(k) Number
FDA product code
LBR
GMDN term
High density lipoprotein (HDL) cholesterol IVD, reagent
Device class
Class I
Regulation number
862.1475
GUDID distribution status
In Commercial Distribution

Other devices from Horiba Instruments Incorporated

See all devices from Horiba Instruments Incorporated →

Properties

  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (11, all answered No)