Skip to content

Portable Oxygen Concentrator

by Qingdao Kingon Medical Science and Technology Co., Ltd. 4 variants

Ref P2-E6Model P2-E,P2-E6,P2-E7

Portable Oxygen Concentrator (P2-E6) is a mobile/portable oxygen concentrator (EU MDR Class IIa; FDA Class II; FDA product code CAW, Generator, Oxygen, Portable) made by Qingdao Kingon Medical Science and Technology Co., Ltd, registered in EUDAMED on 15 Mar 2022 (Basic UDI-DI 697188289P2-ENU) with CE/MDR certificate FI25/1008016 valid until 5 Jun 2030, cleared under FDA 510(k) K210371 on 3 Jun 2022 and listed in FDA GUDID since 10 Jun 2022 (UDI-DI 06971882890406), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

5 Jun 2030

CE MDR certificate

FDA recalls

None found

in data synced 22 Oct 2026

Documents

1 certificate

Certifier SGS FIMKO OY

510(k) K210371

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED NumberFI25/1008016 Date28 Aug 2026IssuedStatusActive expires 5 Jun 2030
United StatesGUDID listing GUDID Number06971882890406 UDI-DI Date10 Jun 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK210371 Date3 Jun 2022DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 29 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 697188289P2-ENU registered 15 Mar 2022 Active· +1 more in the status table
  • FDA 510(k) K210371 decided 3 Jun 2022 Active
  • FDA GUDID UDI-DI 06971882890406 listed 10 Jun 2022 Listed

Certificates

1 certificate · EUDAMED

EUDAMED certificates (1)
  • FI25/1008016 Active Supplemented

    Quality management system EU MDR

    Certifier
    SGS FIMKO OY 0598
    Issued
    28 Aug 2026
    Expires
    5 Jun 2030
    Reason
    Other

Timeline

5 dated events

  1. Registered EUDAMED 697188289P2-ENU
  2. Cleared FDA 510(k) K210371
  3. Listed FDA GUDID 06971882890406
  4. Certificate issued EUDAMED FI25/1008016
  5. Certificate expires EUDAMED FI25/1008016

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Portable Oxygen Concentrator EUDAMED
Rhythm Healthcare GUDID
Generic name
Mobile/portable oxygen concentrator
Model / reference
P2-E, P2-E6, P2-E7
Primary DI / UDI-DI
06971882890406 EUDAMED
06971882890093 GUDID
Basic UDI-DI
697188289P2-ENU
Direct marketing DI
06971882890406
510(k) Number
FDA product code
CAW
EMDN code
Z12159004 Oxygen concentrators
GMDN term
Mobile/portable oxygen concentrator
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
868.5440
System or procedure pack
Procedure pack which is a device in itself
EU registration type
Standard device
EU market of registration
Ireland
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Primary DI / UDI-DIEUDAMED
06971882890406
GUDID
06971882890093
Device classEUDAMED
Class IIa
GUDID
Class II

The registries describe this device under different primary UDI-DIs (EUDAMED lists 06971882890406; FDA GUDID lists 06971882890093), so their flags are not compared. Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CN-MF-000018407
Authorised representative
Wellkang Ltd XI-AR-000001836

Similar devices in this category

Other devices filed under OXYGEN CONCENTRATORS.

Other devices from Qingdao Kingon Medical Science and Technology Co., Ltd

See all devices from Qingdao Kingon Medical Science and Technology Co., Ltd →

Properties

  • Single use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)