Skip to content

Portrait Core Services CSSXB

by GE Medical Systems Information Technologies, Inc. United States EUDAMEDGUDID

Ref 5933539

Product code DRGEMDN Z1203020292

Regulatory status

as of 24 Oct 2026

Recall ongoing. 4 ongoing FDA recalls. See recalls

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number00195278659446 UDI-DIDate30 Apr 2024ListedStatusIn distribution
European UnionCE/MDR EUDAMED Number8406821BUG00424HE Basic UDI-DIDate17 Jan 2024RegisteredStatusActive

Coverage

2 jurisdictions

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaSwedenFinlandFinlandSwedenFinlandFinlandSwedenSwedenLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyGermanyPolandPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaPolandFranceFranceAustriaHungaryRomaniaFranceFranceSloveniaBulgariaPortugalSpainSpainItalySpainSpainCroatiaGreeceMaltaCyprus
  • Active
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Certificates: none listed in EUDAMED

Recalls

4 recalls · 4 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-3036-2026 FDA Class II initiated 20 Jul 2026
    • Ongoing Z-3037-2026 FDA Class II initiated 20 Jul 2026

    Software issue may result in a loss of patient monitoring at the Hub and Central Viewer. In addition, all alarm settings could be reset to factory defaults following the update and will not follow the alarm settings previously configured for each patient or care area.

    • Ongoing Z-2878-2026 FDA Class II initiated 10 Jul 2026

    Portrait Core Services Software version V1.2.0 Security Vulnerability

    • Ongoing Z-0918-2025 FDA Class II initiated 6 Dec 2024

    There is a software issue that can result in the loss of patient monitoring on the Portrait Central Viewer Application after 425 days of continuous run-time.

Specification

EUDAMED · GUDID · synced 22 Oct 2026

Trade Name
Portrait Core Services CSSXB EUDAMED
Portrait CSSXB GUDID
Generic Name
Bedside information system application software
Model / Ref / Catalog
5933539, CSSXB
Primary DI / UDI-DI
00195278659446
Basic UDI-DI
8406821BUG00424HE
Direct Marketing DI
00195278659446
510(k) Number
FDA Product Code
DRG, MSX, DQA, MWI, BZQ
EMDN Code
Z1203020292 Multi-parameter monitors - medical device software
GMDN Term
Bedside information system application software
Device Class
Class IIb EUDAMED
Class II GUDID
Regulation Number
870.2910, 870.2300, 870.2700, 868.2375
Market of Registration
France
Commercial Distribution
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
5933539
GUDID
CSSXB
Device ClassEUDAMED
Class IIb
GUDID
Class II

Manufacturer details

EUDAMED SRN
US-MF-000017529
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Other devices from Ge Medical Systems Information Technologies, Inc.

See all devices from Ge Medical Systems Information Technologies, Inc. →

Properties & raw data

Show properties, registry sources and raw records
  • Prescription Use
  • Lot / Batch Number
Other properties (22)
  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Expiration Date: No
  • Manufacturing Date: No

Sources (2)

  • EUDAMED 985471f3-b9a3-4a4c-9ba2-17bd4e1329da 61 fields · synced 22 Oct 2026
  • FDA UDI 21a2a058-8bc2-4bb8-bfaf-87db87238b18 35 fields · synced 29 May 2026