Skip to content

Possis Angiojet Rapid Thombectomy Catheters--F105 Catheter Model 3030C, LF140 Catheter Model 3040C

by Possis Medical, Inc.

510(k) K972610

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK972610 Date11 Apr 2000ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
QEZ
Device Class
Class II
Regulation
21 CFR Part 870.5150
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The AngioJet Rapid Thrombectomy Catheters are aspiration thrombectomy catheters designed to mechanically fragment and remove thrombus within the vascular system. These devices operate by delivering high-pressure saline jets to disrupt clots while simultaneously aspirating the debris through a distal port, facilitating clearance of occlusive material in arteries and venous access grafts.

Used in interventional cardiology and vascular procedures, these catheters are advanced percutaneously over a guidewire to the target lesion. Supplied as single-use devices, they require pairing with a dedicated pump system for operation. The catheters are classified under FDA’s Class II regulatory framework, with clearance via a 510(k) submission. Sterility and compatibility with standard imaging modalities, including MRI safety considerations, are addressed in the device specifications.

Other devices from Possis Medical, Inc.

See all devices from Possis Medical, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the AngioJet Rapid Thrombectomy Catheters 3030C and 3040C?

    The AngioJet Rapid Thrombectomy Catheters 3030C and 3040C are designed to mechanically fragment and remove thrombus (clots) within the vascular system. They operate by delivering high-pressure saline jets to disrupt clots while simultaneously aspirating the debris through a distal port, effectively clearing occlusive material from arteries and venous access grafts. This dual-action approach helps restore blood flow during interventional cardiology and vascular procedures.

  • How are these catheters supplied and used in clinical settings?

    The AngioJet Rapid Thrombectomy Catheters are supplied as single-use devices, meaning each catheter is intended for one procedure only. They are advanced percutaneously over a guidewire to the target lesion, where they are paired with a dedicated pump system to generate the high-pressure saline jets required for clot fragmentation and aspiration. This setup ensures precise and controlled removal of thrombus during interventions.

  • Are the AngioJet catheters sterile, and what considerations should be taken for storage?

    The AngioJet Rapid Thrombectomy Catheters are supplied in a sterile condition, ensuring safety for single-use procedures. Storage should follow manufacturer guidelines to maintain sterility and functionality. Typically, this involves keeping the catheters in their original packaging, away from direct sunlight, extreme temperatures, and moisture, until ready for use. Always verify the expiration date and storage instructions provided with the device.

  • What are the key differences between the 3030C and 3040C models?

    The 3030C and 3040C models are part of the AngioJet Rapid Thrombectomy Catheter line, with distinctions likely tied to their specific catheter dimensions or intended use within different vascular contexts. While the exact technical specifications (e.g., diameter, length, or flow rates) are not detailed here, these models are designed to address varying clinical scenarios in interventional cardiology and vascular procedures. For precise selection, refer to the manufacturer’s technical documentation or consult with a medical professional.

  • Can these catheters be reused, or are they intended for single-use only?

    The AngioJet Rapid Thrombectomy Catheters are explicitly designed for single-use only. Reusing these devices is not recommended due to potential risks of contamination, device degradation, or compromised performance. Single-use ensures patient safety and maintains the device’s efficacy for its intended purpose, adhering to best practices in medical device usage.