Identity
- Trade Name
- PremierPro Air Transfer Mats FDA UDI
- Generic Name
- Patient transfer system, powered FDA UDI
- Device Name
- Reusable INTENDED USE/ CONTRAINDICATIONS PrernierPro'" Air Transfer Mats are indicated for patients • Who are unable to transfer or turn by their own effort. both assisted and unassisted • Whose size and weight present possible risks to caregivers involved in the transfer of the patient PRECAUTIONS & WARNINGS • Use two or more caregivers during patient transfers • Do not use transfer mat until user manual is reviewed. • Do not leave patient unattended on inflated transfer mat • Do not attempt to move patient on uninflated transfer mat. • The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg) AIR SUPPLY Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed. INSTRUCTIONS FOR USE 1. Transfer surfaces should be close together and equal height or a slightly lower destination surface. 2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose. 3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation. 5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered. 6. Raise side rails, disconnect t air hose and undo safety straps. 7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. FDA UDI
- Model / Reference
- 3721 FDA UDI
- Description
- Reusable INTENDED USE/ CONTRAINDICATIONS PrernierPro'" Air Transfer Mats are indicated for patients • Who are unable to transfer or turn by their own effort. both assisted and unassisted • Whose size and weight present possible risks to caregivers involved in the transfer of the patient PRECAUTIONS & WARNINGS • Use two or more caregivers during patient transfers • Do not use transfer mat until user manual is reviewed. • Do not leave patient unattended on inflated transfer mat • Do not attempt to move patient on uninflated transfer mat. • The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg) AIR SUPPLY Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed. INSTRUCTIONS FOR USE 1. Transfer surfaces should be close together and equal height or a slightly lower destination surface. 2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose. 3. Avoid having obstructions in path of transfer including lines and hoses 4. Hold onto handles during inflation. 5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered. 6. Raise side rails, disconnect t air hose and undo safety straps. 7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient. FDA UDI
Identifiers
- Catalog Number
- 3721 FDA UDI
- Primary DI / UDI-DI
- 00818566019233 FDA UDI
- FDA Product Code
- FRZ FDA UDI
- GMDN Term
- Patient transfer system, powered FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 880.6775 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
Yes
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
No
FDA UDI
MR Safe FDA UDI
Dimensions & Sizes
- Size
- Length — 34 Inch FDA UDI
Category: Patient transfer system, powered
PremierPro Air Transfer Mats by Svs Llc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Patient transfer system, powered.
- HoverMatt — Hovertech International · Class II
- HoverSling Repositiong Sling-TVA — Hovertech International · Class II
- Single Patient Use HoverMatt — Hovertech International · Class II
- Single Patient Use HoverMatt — Hovertech International · Class II
- HoverMatt SPU Plus HoverCover — Hovertech International · Class II
- Sprint 200 — L I N E T spol. s r.o. · Class II
- AirDrive Caddie™ — Qfix · Class I
- Single Patient Use HoverMatt — Hovertech International · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Svs Llc
Sources (1)
- FDA UDI a1099ea3-8a54-417f-9714-4976c53b99dc 36 fields · synced May 30, 2026