Pressure Injectable Arrowg+ard Blue Advance(R) Two-Lumen PICC

by Arrow International LLC (Subsidiary of Teleflex Incorporated)

Ref IDLX-45552-HPK

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

Not listed

EUDAMED holds no validity date

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number08019020000000000000050K7 Basic UDI-DI 10801902222043UDI-DIDate20 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10801902222043 UDI-DI Date8 May 2026ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

11 recalls · 1 ongoing · FDA

    • Ongoing Z-2378-2026 FDA Class I initiated 21 Apr 2026

    Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.

  • 4 recalls, same reason

    • Terminated Z-1822-2019 FDA Class II initiated 23 Apr 2019
    • Terminated Z-1820-2019 FDA Class II initiated 23 Apr 2019
    • Terminated Z-1811-2019 FDA Class II initiated 23 Apr 2019
    • Terminated Z-1819-2019 FDA Class II initiated 23 Apr 2019

    Lidstock states the incorrect expiration date for the product

    • Terminated Z-1327-2018 FDA Class II initiated 22 Dec 2017 on shared 510(k) K112896

    Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.

    • Terminated Z-0996-2018 FDA Class II initiated 27 Nov 2017

    Some of the products listed in the recall may be missing a sticker that contains the lot number, expiration date, and Unique Device Identification (UDI) information.

    • Terminated Z-2698-2017 FDA Class II initiated 12 Jun 2017

    Arrow is recalling additional lots that were identified as part of an active recall. Arrow is recalling the affected product due to the possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter.

    • Terminated Z-2331-2017 FDA Class II initiated 9 May 2017

    Arrow International is recalling the affected product because the packaging may not be completely sealed, which may compromise sterility.

    • Terminated Z-1705-2017 FDA Class II initiated 3 Mar 2017

    Arrow International, Inc. notified its customers who received the affected Antimicrobial/Antithrombogenic PICC Kits, that the kits were being recalled due to a labeling error. The lidstock on some of the kits reads CDC-45541-HPK1A, while the banner card on the side of the kit reads CDC-45052-HPK1A. Other kits may list CDC-45052-HPK1A on the lidstock and CDC-45541-HPK1A on the banner card. The affected lot numbers are 23F16C0851, 23F16A0727, and 23F16C0844.

    • Terminated Z-0207-2016 FDA Class II initiated 16 Oct 2015

    Possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter. Although the issue does not pose a significant risk to the patient, it may cause a delay of treatment when placing the catheter.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade Name
Pressure Injectable Arrowg+ard Blue Advance(R) Two-Lumen PICC EUDAMED
Arrow GUDID
Generic Name
Peripherally-inserted central venous catheter
Device Name
Arrowg+ard Blue Advance (AGBA) Peripherally Inserted Central Catheter (PICC) Product
Model / Ref / Catalog
IDLX-45552-HPK, IPN930593
Primary DI / UDI-DI
10801902222043
Basic UDI-DI
08019020000000000000050K7
510(k) Number
FDA Product Code
LJS
EMDN Code
C01020102 Central i.v. multi-lumen catheters, peripheral access
GMDN Term
Peripherally-inserted central venous catheter
Device Class
Class III EUDAMED
Class II GUDID
Regulation Number
880.5970
Medical Purpose
The Pressure Injectable PICC is indicated for short-term or long-term peripheral access to the central venous system for intravenous therapy, blood sampling, infusion, pressure injection of contrast media, and allows for central venous pressure monitoring. The maximum pressure of pressure injector equipment used with the Pressure Injectable PICC may not exceed 300 psi (2068.4 kPa). The maximum pressure injection flow rate ranges from 4 mL/sec to 6 mL/sec. Refer to the product specific labeling for the maximum pressure injection flow rate for the specific lumen being used for pressure injection. Arrowg+ard Blue Advance Protection treatment on the external surface of the catheter body as well as the entire fluid pathway of the catheter has been shown to be effective in reducing microbial colonization and thrombus accumulation on catheter surfaces. Antimicrobial and antithrombogenic effectiveness were evaluated using in vitro and in vivo test methods, and no correlation between these testing methods and clinical outcome has currently been ascertained. It is not intended to be used for the treatment of existing infections or vein thrombosis.
GUDID distribution status
In Commercial Distribution
MRI Safety
MR Safe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
IDLX-45552-HPK
GUDID
IPN930593
Device ClassEUDAMED
Class III
GUDID
Class II

Manufacturer details

EUDAMED SRN
US-PR-000023158

Other devices from Arrow International LLC (Subsidiary of Teleflex Incorporated)

See all devices from Arrow International LLC (Subsidiary of Teleflex Incorporated) →

Properties

  • Sterile
  • Single Use
  • Implantable
  • Convenience Kit
  • Lot / Batch Number
  • Expiration Date

Other properties (8)

  • Contains Latex: No
  • Prescription Use: No
  • Over-the-Counter: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Manufacturing Date: No