Pressure Injectable Arrowg+ard Blue Advance(R) Two-Lumen PICC
by Arrow International LLC (Subsidiary of Teleflex Incorporated)
Ref IDLX-45552-HPK
Active
Valid until
Not listed
FDA recalls
1 ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08019020000000000000050K7 10801902222043 | Date20 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10801902222043 | Date8 May 2026 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-2378-2026
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
-
- Terminated Z-1822-2019
- Terminated Z-1820-2019
- Terminated Z-1811-2019
- Terminated Z-1819-2019
Lidstock states the incorrect expiration date for the product
-
- Terminated Z-1327-2018
Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.
-
- Terminated Z-0996-2018
Some of the products listed in the recall may be missing a sticker that contains the lot number, expiration date, and Unique Device Identification (UDI) information.
-
- Terminated Z-2698-2017
Arrow is recalling additional lots that were identified as part of an active recall. Arrow is recalling the affected product due to the possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter.
-
- Terminated Z-2331-2017
Arrow International is recalling the affected product because the packaging may not be completely sealed, which may compromise sterility.
-
- Terminated Z-1705-2017
Arrow International, Inc. notified its customers who received the affected Antimicrobial/Antithrombogenic PICC Kits, that the kits were being recalled due to a labeling error. The lidstock on some of the kits reads CDC-45541-HPK1A, while the banner card on the side of the kit reads CDC-45052-HPK1A. Other kits may list CDC-45052-HPK1A on the lidstock and CDC-45541-HPK1A on the banner card. The affected lot numbers are 23F16C0851, 23F16A0727, and 23F16C0844.
-
- Terminated Z-0207-2016
Possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter. Although the issue does not pose a significant risk to the patient, it may cause a delay of treatment when placing the catheter.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Pressure Injectable Arrowg+ard Blue Advance(R) Two-Lumen PICC EUDAMEDArrow GUDID
- Generic Name
- Peripherally-inserted central venous catheter
- Device Name
- Arrowg+ard Blue Advance (AGBA) Peripherally Inserted Central Catheter (PICC) Product
- Model / Ref / Catalog
- IDLX-45552-HPK, IPN930593
- Primary DI / UDI-DI
- 10801902222043
- Basic UDI-DI
- 08019020000000000000050K7
- 510(k) Number
- FDA Product Code
- LJS
- EMDN Code
- C01020102 Central i.v. multi-lumen catheters, peripheral access
- GMDN Term
- Peripherally-inserted central venous catheter
- Device Class
- Class III EUDAMEDClass II GUDID
- Regulation Number
- 880.5970
- Medical Purpose
- The Pressure Injectable PICC is indicated for short-term or long-term peripheral access to the central venous system for intravenous therapy, blood sampling, infusion, pressure injection of contrast media, and allows for central venous pressure monitoring. The maximum pressure of pressure injector equipment used with the Pressure Injectable PICC may not exceed 300 psi (2068.4 kPa). The maximum pressure injection flow rate ranges from 4 mL/sec to 6 mL/sec. Refer to the product specific labeling for the maximum pressure injection flow rate for the specific lumen being used for pressure injection. Arrowg+ard Blue Advance Protection treatment on the external surface of the catheter body as well as the entire fluid pathway of the catheter has been shown to be effective in reducing microbial colonization and thrombus accumulation on catheter surfaces. Antimicrobial and antithrombogenic effectiveness were evaluated using in vitro and in vivo test methods, and no correlation between these testing methods and clinical outcome has currently been ascertained. It is not intended to be used for the treatment of existing infections or vein thrombosis.
- GUDID distribution status
- In Commercial Distribution
- MRI Safety
- MR Safe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | IDLX-45552-HPK | IPN930593 |
| Device Class | Class III | Class II |
Manufacturer details
- EUDAMED SRN
- US-PR-000023158
Other devices from Arrow International LLC (Subsidiary of Teleflex Incorporated)
See all devices from Arrow International LLC (Subsidiary of Teleflex Incorporated) →
Properties
Other properties (8)
- Contains Latex: No
- Prescription Use: No
- Over-the-Counter: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Manufacturing Date: No