Prestige Coil System PRES0153CXPPL
by Balt USA LLC
Ref PRES0153CXPPL
Prestige Coil System PRES0153CXPPL is a device classified as Class IIb in the EU and Class II in the US made by Balt USA LLC, registered in EUDAMED on 13 Oct 2026 (Basic UDI-DI B-00840303708971), cleared under FDA 510(k) K220699 on 8 Apr 2022 (1 earlier submission) and listed in FDA GUDID since 22 Nov 2024 (UDI-DI 00840303708971), active as of 24 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
7 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00840303708971 00840303708971 | Date13 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00840303708971 | Date22 Nov 2024 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK220699 | Date8 Apr 2022 | StatusActive |
Official records
- EUDAMED public site B-00840303708971
- AccessGUDID record 00840303708971
- AccessGUDID record 00818053027291
- FDA 510(k) database K220699
- FDA 510(k) database K200030
Across registries
- EUDAMED Basic UDI-DI B-00840303708971 registered 13 Oct 2026 Active
- FDA 510(k) K220699 decided 8 Apr 2022 Active
- FDA GUDID UDI-DI 00840303708971 listed 22 Nov 2024 Listed
Recalls
-
- Ongoing Z-1988-2025
- Ongoing Z-1989-2025
Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification.
-
- Ongoing Z-1042-2024
- Ongoing Z-1041-2024
Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli.
-
- Ongoing Z-0103-2023
Product pouch label does not match up with carton label
-
- Ongoing Z-1680-2022
Products were released to customers prior to the approval and release of a test report authorizing the use of an existing material from an alternate supplier.
-
- Ongoing Z-0660-2022
Due to Label/Pouch mix-up. Pouches incorrectly labeled. Incorrect shelf carton label or pouch label due to inadequate manufacturing line clearance. As a result of this labeling mix-up, there is the possibility of inadvertently selecting the incorrect coil size for the procedure potentially causing some harms like vessel damage, an inability to treat with said device and potential rupture of the aneurysm.
Timeline
- Recall initiated FDA recalls Z-0660-2022
- Cleared FDA 510(k) K220699
- Recall initiated FDA recalls Z-1680-2022
- Recall initiated FDA recalls Z-0103-2023
- Recall initiated FDA recalls Z-1042-2024
- Recall initiated FDA recalls Z-1041-2024
- Listed FDA GUDID 00840303708971
- Recall initiated FDA recalls Z-1988-2025
- Recall initiated FDA recalls Z-1989-2025
- Registered EUDAMED B-00840303708971
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Prestige Coil System
- Generic name
- Non-neurovascular embolization coil
- Device name
- Peripheral Embolization Device
- Model / Ref / Catalog
- PRES0153CXPPL
- Primary DI / UDI-DI
- 00840303708971, 00818053027291
- Basic UDI-DI
- B-00840303708971
- FDA product code
- KRD
- EMDN code
- Z12109001 Detachable coil equipment for brain aneurysms
- GMDN term
- Non-neurovascular embolization coil
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.3300
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under NEUROLOGY AND NEUROSURGERY INSTRUMENTS.
- AVALANCHE® PLUS System Link Kabel 20-0101 by Dr. Langer Medical GmbH
- Cadwell 0029 by Xi'an Friendship Medical Electronics Co., Ltd.
- Cadwell 0024 by Xi'an Friendship Medical Electronics Co., Ltd.
- ISIS 504285 by inomed Medizintechnik GmbH
- Stimulationskabel für TWISTER® TC, 6 Kontakte 20-0201 by Dr. Langer Medical GmbH
- ISIS 504006 by inomed Medizintechnik GmbH
- NIM Vital NIM4CM01 by Medtronic Xomed Inc
- Cadwell Guardian 190312-200 by Cadwell Industries, Inc.
- EpiMonitor by Empatica EpiMonitor-AND by Empatica S.r.L.