Primary Solution Set With Universal Spike, Injection Site And Male Luer Lock
by Churchill Medical Systems, Inc.
510(k) K011336
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK011336 | Date12 Jun 2001 | StatusActive |
Recalls
-
- Terminated Z-1332-2011
- Terminated Z-1322-2011
- Terminated Z-1324-2011
- Terminated Z-1321-2011
- Terminated Z-1320-2011
- Terminated Z-1328-2011
- Terminated Z-1319-2011
- Terminated Z-1329-2011
Routine testing conducted to challenge the success of sterilization was not fully completed for sterile products.
-
- Terminated Z-1639-2010
Bond between the spike and needle may leak, break or detach resulting in leakage or spillage of chemotherapeutic agents
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- FPA
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5440
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 21 Sep 2026
This device is a primary solution set with universal spike, injection site and male luer lock. It is designed for intravenous administration of fluids and medications.
The set is supplied as a single-use, sterile infusion set. It includes a universal spike, male swivel luer lock connector, roller clamp, drip chamber with 15 micron filter, and a Y-injection site located 6 inches from the distal end. The tubing primes at 15.58 mL and delivers fluid at a rate of 20 drops per milliliter. It is individually blister-packaged in quantities of 50 per box and is intended for use in general hospital settings.
Other devices from Churchill Medical Systems, Inc.
Questions
AI-generated answers, 21 Sep 2026
What is this device used for?
This device is designed for the intravenous administration of fluids and medications in general hospital settings. It enables safe and controlled delivery of therapeutic solutions through a sterile fluid path that includes a universal spike for container access, a Y-injection site for medication addition, and a male luer lock for secure connection to IV catheters or extension sets.
Is this infusion set sterile and single-use?
Yes, the set is supplied as a sterile, single-use device. It is individually blister-packaged to maintain sterility until point of use and is intended for one-time application only. Reuse is not recommended as it could compromise sterility, increase infection risk, and lead to mechanical failure or cross-contamination.
What components are included in this primary solution set?
The set includes a universal spike for piercing IV solution containers, a male swivel luer lock connector for secure attachment to IV catheters, a roller clamp for flow rate control, a drip chamber equipped with a 15 micron filter to remove particulates, and a Y-injection site positioned 6 inches from the distal end for intermittent medication administration without disconnecting the line.
How is this device packaged and what is its priming volume?
The infusion set is individually blister-packaged and supplied in boxes of 50 units. Its fluid path primes at 15.58 mL, which is the volume required to fill the tubing and remove air before initiating infusion. This priming volume should be accounted for when administering medications to ensure accurate dosing, especially in low-volume or pediatric cases.
What is the drop factor of this infusion set?
The set delivers fluid at a rate of 20 drops per milliliter (20 gtt/mL), which is the drop factor used to calculate infusion rates when using gravity-fed administration. This specification allows clinicians to regulate flow by adjusting the roller clamp and counting drops in the drip chamber, ensuring precise delivery of fluids or medications as prescribed.