Prismaflex M100 set
Ref 106697MDR
Active
Valid until
Not listed
FDA recalls
2 ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number7332414VA0000262Z 07332414201340 | Date22 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07332414201340 | Date27 Mar 2026 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-1227-2026
There is a potential dislodgement of the Prismaflex Set deaeration chamber from the Prismaflex Control Unit.
-
- Ongoing Z-0081-2023
Within the current Prismaflex set IFU (instructions for use), there is a mistranslation of the Extonian (Eesti) text. The mistranslation indicates contradictory information related to the patient body weight restrictions.
-
- Terminated Z-2378-2021
Products labeled as sterile were distributed, but may not have been sterilized. " Baxter confirmed Steril Milano observed nonconformances that were not reported to Baxter. Data was manipulated to appear to be conforming
-
- Terminated Z-2201-2014
- Terminated Z-2202-2014
Gambro initiated a field action on the Prisma and Prismaflex sets due to breakages of connectors resulting in leakage of liquid or blood.
-
- Terminated Z-0695-2007
Under certain conditions, * an excessive amount of anticoagulant may be infused into the patient. (* interruption of a self-test by an alarm and obstruction of the access lines)
-
- Terminated Z-0032-2007
A potential risk of infusing air or infusion fluid to the patient during dialysis. Also, a possibility of an incorrect scale reading of the amount of patient fluid removal.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Prismaflex M100 set EUDAMEDPrismaflex Set M100 GUDID
- Generic Name
- Haemofilter
- Device Name
- Prismaflex M set and Prismaflex ST set
- Model / Ref / Catalog
- 106697MDR
- Primary DI / UDI-DI
- 07332414201340
- Basic UDI-DI
- 7332414VA0000262Z
- 510(k) Number
- FDA Product Code
- KDI
- EMDN Code
- F01060303 DIALYSERS - UFC > 35 ml/h/mmHg, SYNTHETIC MEMBRANES
- GMDN Term
- Haemofilter
- Device Class
- Class IIb EUDAMEDClass II GUDID
- Regulation Number
- 876.5860
- EU market of registration
- Italy
- GUDID distribution status
- Not in Commercial Distribution
- Size
- Width — 22 CentimeterWeight — 814 GramHeight — 9 CentimeterLength — 27 Centimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device Class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- CH-MF-000038981
- Authorised representative
- Vantive S.r.l. IT-AR-000041309
Other devices from Vantive Health GmbH
Properties
Other properties (18)
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No