Skip to content

Prismaflex Set HF1400

by Gambro Industries

Prismaflex Set HF1400 (107142) is a haemofilter (FDA Class II; FDA product code KDI, Dialyzer, high permeability with or without sealed dialysate system) made by Gambro Industries, cleared under FDA 510(k) K042938 on 6 Jan 2005 and listed in FDA GUDID since 5 Oct 2015 (UDI-DI 07332414069315), active as of 23 Oct 2026. 7 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

510(k) K042938

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number07332414069315 UDI-DI Date5 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK042938 Date6 Jan 2005DecidedStatusActive

Official records

From the FDA record

Device description
The Prismaflex HF1400 set is indicated for use only with the PrismaFlex system or with the PrisMax system (in countries where PrisMax is cleared or registered) in providing continuous fluid management and renal replacement therapies. The system is intended for patients who have acute renal failure, fluid overload, or both.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K042938 decided 6 Jan 2005 Active
  • FDA GUDID UDI-DI 07332414069315 listed 5 Oct 2015 Listed

Recalls

7 recalls · 4 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1230-2026 FDA Class II initiated 6 Jan 2026
    • Ongoing Z-1229-2026 FDA Class II initiated 6 Jan 2026

    There is a potential dislodgement of the Prismaflex Set deaeration chamber from the Prismaflex Control Unit.

  • 2 recalls, same reason

    • Ongoing Z-0083-2023 FDA Class II initiated 14 Sep 2022
    • Ongoing Z-0085-2023 FDA Class II initiated 14 Sep 2022

    Within the current Prismaflex set IFU (instructions for use), there is a mistranslation of the Extonian (Eesti) text. The mistranslation indicates contradictory information related to the patient body weight restrictions.

    • Terminated Z-2379-2021 FDA Class II initiated 22 Jul 2021

    Products labeled as sterile were distributed, but may not have been sterilized. Baxter confirmed Steril Milano observed nonconformances that were not reported to Baxter Data was manipulated to appear to be conforming

  • 2 recalls, same reason

    • Terminated Z-2204-2014 FDA Class II initiated 18 Jul 2014
    • Terminated Z-2205-2014 FDA Class II initiated 18 Jul 2014

    Gambro initiated a field action on the Prisma and Prismaflex sets due to breakages of connectors resulting in leakage of liquid or blood.

Timeline

9 dated events

  1. Cleared FDA 510(k) K042938
  2. Recall initiated FDA recalls Z-2204-2014
  3. Recall initiated FDA recalls Z-2205-2014
  4. Listed FDA GUDID 07332414069315
  5. Recall initiated FDA recalls Z-2379-2021
  6. Recall initiated FDA recalls Z-0083-2023
  7. Recall initiated FDA recalls Z-0085-2023
  8. Recall initiated FDA recalls Z-1230-2026
  9. Recall initiated FDA recalls Z-1229-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Prismaflex Set
Generic name
Haemofilter
Model / Ref / Catalog
HF1400, 107142
Primary DI / UDI-DI
07332414069315
510(k) Number
FDA product code
KDI
GMDN term
Haemofilter
Device class
Class II
Regulation number
876.5860
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code KDI (Dialyzer, high permeability with or without sealed dialysate system).

Other devices from Gambro Industries

  • Prismaflex Set 107636US Open recall

    Class II
  • Prismaflex Set HF1000 Open recall

    Class II
  • Prismaflex Set M150 Open recall

    Class II
  • Diaclear 106887

    Class II

See all devices from Gambro Industries →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (9, all answered No)