Procainamide Assay for the Bayer Immuno 1 System

by Bayer Corp.

510(k) K971716

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 5 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 5 Oct 2026. What this means

Regulatory status

as of registry sync 5 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK971716 Date27 Jun 1997ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 5 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
LAR
Device Class
Class II
Regulation
21 CFR Part 862.3320
Advisory Committee
Clinical Toxicology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Procainamide Assay for the Bayer Immuno 1 System is an enzyme immunoassay designed to quantitatively measure procainamide concentrations in human serum or plasma. Procainamide is an antiarrhythmic drug used to treat cardiac arrhythmias, and its levels are monitored to ensure therapeutic efficacy and prevent toxicity. This assay employs the Enzyme Multiplied Immunoassay Technique (EMIT) to provide accurate concentration data for clinical decision-making. It is classified as a clinical toxicology device, supporting diagnosis and management of procainamide overdose or therapeutic monitoring.

This assay is intended for use in clinical laboratories and is supplied as a reagent kit for the Bayer Immuno 1 System. It is a single-use, in vitro diagnostic device with no specified sterility requirements beyond standard laboratory practices. The device operates within the constraints of FDA 510(k) clearance under product code LAR, adhering to regulatory standards for enzyme immunoassays. Storage and handling follow manufacturer guidelines to maintain assay integrity, though specific conditions (e.g., temperature, expiration) are detailed in accompanying documentation.

Other devices from Bayer Corp.

See all devices from Bayer Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Procainamide Assay for the Bayer Immuno 1 System used for?

    This assay measures procainamide concentrations in human serum or plasma to monitor therapeutic levels and prevent toxicity. Procainamide is an antiarrhythmic drug used to treat cardiac arrhythmias, and its precise quantification aids clinicians in adjusting dosages for optimal efficacy while avoiding adverse effects like overdose.

  • How is the Procainamide Assay supplied, and is it single-use?

    The assay is supplied as a reagent kit designed exclusively for the Bayer Immuno 1 System. It is intended for single-use only, adhering to standard in vitro diagnostic practices. Each kit is packaged for one-time use to ensure accuracy and reliability in clinical toxicology testing.

  • Does the Procainamide Assay require sterility beyond standard laboratory practices?

    No specific sterility requirements beyond routine laboratory hygiene are stated for this assay. Since it is an in vitro diagnostic device used in controlled clinical laboratory settings, adherence to general aseptic techniques during handling and testing is expected to maintain integrity and prevent contamination.

  • What type of immunoassay technique does the Procainamide Assay use?

    The assay employs the Enzyme Multiplied Immunoassay Technique (EMIT), a widely recognized method for enzyme immunoassays. EMIT enhances sensitivity and specificity by amplifying the enzymatic reaction, providing accurate and reproducible procainamide concentration measurements for clinical decision-making.

  • How should the Procainamide Assay be stored, and what documentation covers storage guidelines?

    Storage conditions are detailed in the accompanying manufacturer documentation, which outlines specific requirements such as temperature and expiration dates. Proper storage is critical to preserve assay integrity and performance, ensuring reliable results when monitoring procainamide levels in patient samples.