PROcovers™ 610-075
by Civco Medical Instruments Co., Inc.
Part of a family of 12 devices: see the family page
Ref 610-075
PROcovers 610-075 is a body-orifice ultrasound imaging transducer cover (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 18 May 2026 (Basic UDI-DI 0841436101TD201C2NS), cleared under FDA 510(k) K970515 on 20 Jun 1997 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 10841436101513), active as of 23 Oct 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0841436101TD201C2NS 10841436101513 | Date18 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10841436101513 | Date22 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK970515 | Date20 Jun 1997 | StatusActive |
Official records
- EUDAMED public site 0841436101TD201C2NS
- AccessGUDID record 10841436101513
- FDA 510(k) database K970515
From the FDA record
- Device description
- Sterile (2 x 20cm) latex cover
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as containing natural rubber latex
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- EUDAMED Basic UDI-DI 0841436101TD201C2NS registered 18 May 2026 Active
- FDA 510(k) K970515 decided 20 Jun 1997 Active
- FDA GUDID UDI-DI 10841436101513 listed 22 Aug 2017 Listed
Timeline
- Cleared FDA 510(k) K970515
- Listed FDA GUDID 10841436101513
- Registered EUDAMED 0841436101TD201C2NS
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- PROcovers™
- Generic name
- Body-orifice ultrasound imaging transducer cover, basic
- Device name
- Intracavity Covers (Latex sterile)
- Model / Ref / Catalog
- 610-075
- Primary DI / UDI-DI
- 10841436101513
- Basic UDI-DI
- 0841436101TD201C2NS
- 510(k) Number
- FDA product code
- ITX
- EMDN code
- T030102 Cover sheaths, instruments and equipments
- GMDN term
- Body-orifice ultrasound imaging transducer cover, basic
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
- Size
- Length — 20 CentimeterWidth — 2 Centimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 10841436101513: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under COVER SHEATHS, INSTRUMENTS AND EQUIPMENTS.
- Barrier Film/Sleeves N/A by WELLMED DENTAL MEDICAL SUPPLY CO.,LTD
- Endo-Boot 00711622 by US Endoscopy
- Barrier Film/Sleeves KPD-001-BIO by WELLMED DENTAL MEDICAL SUPPLY CO.,LTD
- Pergo 05TD3684 by Pergo Medikal ve Ilac Sanayi A.S.
- CinchPad™ SPX-017-25 by Boston Scientific
- Endo covers ES-02 by Surgitools(Shanghai)Medical Instruments Co.,Ltd.
- Universal Endoscopic Tip Guard GAR107 by GA HEALTH COMPANY LIMITED
- Ultrasound Probe Cover GQK-60-44-240 by Shenzhen Rising Medical Co., Ltd
- CMR 20302 by PERGO MEDIKAL VE ILAC SANAYI ANONIM SIRKETI
- ZEYNİ 103-022-B by ZEYNI MEDIKAL TEKSTIL INSAAT SAN. VE TIC. LTD. STI