by Oscor Medical Corp.

510(k) K913201

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK913201 Date23 Sep 1991ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Products Implant Pacing Lead, Tined, Modification
510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, designed for transvenous implantation to deliver electrical stimulation to the heart. The tined design enhances fixation within cardiac tissue, ensuring stable positioning for chronic pacing applications in patients with bradycardia or conduction disorders.

The lead is supplied sterile and intended for single-use implantation by qualified healthcare professionals in clinical settings such as cardiac catheterization labs or operating rooms. It adheres to FDA 510(k) clearance under the Cardiovascular advisory committee, with a classification as a Class III device under regulation 870.3680. Multiple model references are listed for regulatory tracking, including FEI numbers such as 3002618605 and 2017865.

Other devices from Oscor Medical Corp.

See all devices from Oscor Medical Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of this tined pacing lead, and how does the tined design benefit patients?

    This device is a permanent pacemaker electrode designed for transvenous implantation to deliver electrical stimulation to the heart. The tined design enhances fixation within cardiac tissue, ensuring stable positioning for chronic pacing applications in patients with bradycardia or conduction disorders. The tines help secure the lead in place, reducing the risk of displacement over time.

  • Is this lead intended for reuse, or is it meant for single-use only? How should it be handled before implantation?

    The lead is sterile and intended for single-use only, meaning it must be used once and then discarded. It is supplied pre-sterilized for clinical settings like cardiac catheterization labs or operating rooms, where qualified healthcare professionals perform the implantation.

  • What regulatory pathway was followed for FDA clearance, and how does this affect its classification?

    This device received FDA 510(k) clearance through a traditional review pathway under the Cardiovascular advisory committee. It is classified as a Class III device (regulation 870.3680), meaning it is subject to stricter regulatory oversight due to its role in life-sustaining or life-supporting functions. The clearance was granted as substantially equivalent to a predicate device.

  • Are there multiple model variants of this lead, and if so, how are they differentiated for regulatory tracking?

    Yes, this lead has multiple model references tracked via FDA Establishment Inspection Report (FEI) numbers, including identifiers like 2017865, 3002618605, and others. These numbers are used for regulatory tracking and compliance but do not indicate functional or clinical differences—each FEI corresponds to a specific batch or variant as filed with the FDA.

  • Where should this lead be stored before use, and are there any special handling instructions?

    Since the lead is sterile and single-use, it should be stored in its original packaging in a clean, dry environment away from direct sunlight or extreme temperatures. The packaging must remain intact until implantation to maintain sterility. Always follow manufacturer instructions for storage conditions, which are typically detailed on the packaging.