Propper Vapor Line PCD (Steam Sterilization Process Challenge Test)

by Propper Mfg. Co., Inc.

510(k) K031152

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK031152 Date17 Aug 2004ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JOJ
Device Class
Class II
Regulation
21 CFR Part 880.2800
Advisory Committee
General Hospital
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Propper Vapor Line PCD is a Steam Sterilization Process Challenge Device, classified as a Physical/Chemical Sterilization Process Indicator. It is designed to verify the effectiveness of steam sterilization cycles in pre-vacuum sterilizers by detecting potential process failures, such as inadequate temperature, pressure, or exposure time. This device helps ensure that sterilization parameters meet regulatory and clinical standards for sterilizing medical instruments and supplies.

The Propper Vapor Line PCD is supplied as a reusable challenge device, intended for use in high-volume sterilization environments. It is not sterile upon receipt and must be processed through the sterilizer alongside the load being tested. The device is compatible with pre-vacuum sterilizers operating at 273.2°F (134°C) and is used in conjunction with a steam sterilization integrator. It is regulated under FDA 510(k) clearance (K031152) and falls under Device Class II (880.2800). Storage and handling follow standard hospital reprocessing procedures.

Other devices from Propper Mfg. Co., Inc.

See all devices from Propper Mfg. Co., Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Propper Vapor Line PCD used for in a sterilization process?

    The Propper Vapor Line PCD is a Steam Sterilization Process Challenge Device designed to verify the effectiveness of steam sterilization cycles in pre-vacuum sterilizers. It detects potential process failures—such as inadequate temperature, pressure, or exposure time—ensuring that sterilization parameters meet regulatory and clinical standards for medical instruments and supplies.

  • Is the Propper Vapor Line PCD single-use or reusable, and how should it be handled?

    The Propper Vapor Line PCD is reusable and must be processed through the sterilizer alongside the load being tested. It is not sterile upon receipt, so it follows standard hospital reprocessing procedures before use. This aligns with its design for high-volume sterilization environments.

  • What type of sterilizers is this device compatible with, and what temperature does it require?

    The Propper Vapor Line PCD is specifically designed for pre-vacuum sterilizers operating at 273.2°F (134°C). It is used in conjunction with a steam sterilization integrator to validate cycle performance under these conditions.

  • How is the regulatory status of this device determined, and what class does it fall under?

    The Propper Vapor Line PCD holds FDA 510(k) clearance (K031152) and is classified as Device Class II under the regulatory category 880.2800 (Physical/Chemical Sterilization Process Indicator). This classification reflects its role as a critical component for ensuring sterilization integrity in medical settings.

  • What should I consider when storing the Propper Vapor Line PCD between uses?

    Since the device is reusable, storage follows standard hospital reprocessing procedures. It should be kept in a clean, dry environment—free from contaminants—until ready for reprocessing and reuse in sterilization cycles. No additional sterility guarantees are provided upon receipt.