Propper Vapor Line PCD (Steam Sterilization Process Challenge Test)
510(k) K031152
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK031152 | Date17 Aug 2004 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- JOJ
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.2800
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 20 Sep 2026
The Propper Vapor Line PCD is a Steam Sterilization Process Challenge Device, classified as a Physical/Chemical Sterilization Process Indicator. It is designed to verify the effectiveness of steam sterilization cycles in pre-vacuum sterilizers by detecting potential process failures, such as inadequate temperature, pressure, or exposure time. This device helps ensure that sterilization parameters meet regulatory and clinical standards for sterilizing medical instruments and supplies.
The Propper Vapor Line PCD is supplied as a reusable challenge device, intended for use in high-volume sterilization environments. It is not sterile upon receipt and must be processed through the sterilizer alongside the load being tested. The device is compatible with pre-vacuum sterilizers operating at 273.2°F (134°C) and is used in conjunction with a steam sterilization integrator. It is regulated under FDA 510(k) clearance (K031152) and falls under Device Class II (880.2800). Storage and handling follow standard hospital reprocessing procedures.
Other devices from Propper Mfg. Co., Inc.
Questions
AI-generated answers, 20 Sep 2026
What is the Propper Vapor Line PCD used for in a sterilization process?
The Propper Vapor Line PCD is a Steam Sterilization Process Challenge Device designed to verify the effectiveness of steam sterilization cycles in pre-vacuum sterilizers. It detects potential process failures—such as inadequate temperature, pressure, or exposure time—ensuring that sterilization parameters meet regulatory and clinical standards for medical instruments and supplies.
Is the Propper Vapor Line PCD single-use or reusable, and how should it be handled?
The Propper Vapor Line PCD is reusable and must be processed through the sterilizer alongside the load being tested. It is not sterile upon receipt, so it follows standard hospital reprocessing procedures before use. This aligns with its design for high-volume sterilization environments.
What type of sterilizers is this device compatible with, and what temperature does it require?
The Propper Vapor Line PCD is specifically designed for pre-vacuum sterilizers operating at 273.2°F (134°C). It is used in conjunction with a steam sterilization integrator to validate cycle performance under these conditions.
How is the regulatory status of this device determined, and what class does it fall under?
The Propper Vapor Line PCD holds FDA 510(k) clearance (K031152) and is classified as Device Class II under the regulatory category 880.2800 (Physical/Chemical Sterilization Process Indicator). This classification reflects its role as a critical component for ensuring sterilization integrity in medical settings.
What should I consider when storing the Propper Vapor Line PCD between uses?
Since the device is reusable, storage follows standard hospital reprocessing procedures. It should be kept in a clean, dry environment—free from contaminants—until ready for reprocessing and reuse in sterilization cycles. No additional sterility guarantees are provided upon receipt.