Pruitt-Inahara Carotid Shunt 400-40-8F/INAHARA-PRUITT Carotid Shunt 500-50-8F
510(k) K960715
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK960715 | Date9 Sep 1996 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- MJN
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.4450
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Pruitt-Inahara Carotid Shunt 400-40-8F and Inahara-Pruitt Carotid Shunt 500-50-8F are intravascular, temporary occluding catheters designed for carotid artery procedures. These devices facilitate temporary arterial access or bypass during surgical interventions, ensuring controlled blood flow while minimizing trauma to the vessel wall.
Supplied as single-use devices, these shunts are intended for use in arteries too small for larger 9 French shunts, with sizes 400-40-8F and 500-50-8F featuring a T-port for patency confirmation and back-bleeding. They are regulated under FDA 510(k) clearance (K960715) and classified as Class II medical devices, adhering to FDA regulation 870.4450. Sterility and MRI safety are not specified in the provided data.
Other devices from Ideas For Medicine, Inc.
Questions
AI-generated answers, 19 Sep 2026
What are the primary uses for the Pruitt-Inahara Carotid Shunt in surgical procedures?
The Pruitt-Inahara Carotid Shunt (models 400-40-8F and 500-50-8F) is designed for temporary arterial access or bypass during carotid artery procedures. It helps control blood flow while minimizing trauma to the vessel wall, making it suitable for cases where smaller arteries require precise intervention that larger catheters cannot accommodate.
Are these shunts intended for single-use or can they be reused?
The Pruitt-Inahara Carotid Shunt is explicitly supplied as a single-use device. This design ensures patient safety and sterility, as reuse could compromise integrity and introduce infection risks.
What sizes are available for the Pruitt-Inahara Carotid Shunt, and how do they differ?
The device comes in two sizes: 400-40-8F and 500-50-8F. Both are tailored for smaller arteries where traditional 9 French shunts are impractical. The T-port feature in both models allows for patency confirmation and back-bleeding, ensuring proper function during use.
How is the regulatory status of this device determined?
The Pruitt-Inahara Carotid Shunt holds FDA 510(k) clearance (K960715) and is classified as a Class II medical device under FDA regulation 870.4450. This classification reflects its intended use as an intravascular, temporary occluding catheter for carotid artery procedures, with a history of substantial equivalence to prior devices.
What should clinicians consider when storing these shunts before use?
While the provided data does not specify storage conditions, as a single-use, sterile medical device, these shunts should be stored in a clean, dry environment away from direct sunlight or extreme temperatures. Proper packaging integrity must be maintained until immediate use to preserve sterility and functionality.