Pulse Generator Model 688

by Burditt & Calkins-Siemens-Elema

510(k) K833519

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK833519 Date30 Jan 1984ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Pulse Generator Model 688 is an implantable pacemaker pulse-generator, designed to regulate cardiac rhythm by delivering electrical impulses to the heart. It falls under the classification of an implantable pacemaker pulse-generator, as defined by regulatory nomenclature authorities.

This device is intended for surgical implantation and is classified as a Class III medical device under FDA regulations. It is supplied sterile and intended for single-use implantation, with no indication of MRI compatibility. The Model 688 was granted FDA 510(k) clearance under the traditional review pathway, with a decision date of January 30, 1984.

Other devices from Burditt & Calkins-Siemens-Elema

See all devices from Burditt & Calkins-Siemens-Elema →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the Pulse Generator Model 688, and how does it function in a clinical setting?

    The Pulse Generator Model 688 is an implantable pacemaker pulse-generator designed to regulate abnormal cardiac rhythms by delivering timed electrical impulses to the heart. It is surgically implanted to ensure consistent pacing when the patient’s natural electrical conduction system fails, helping maintain a stable heart rate and rhythm for patients with bradycardia or other pacing-dependent conditions.

  • Is the Pulse Generator Model 688 intended for reuse, or is it meant to be implanted as a single-use device?

    The Pulse Generator Model 688 is explicitly supplied sterile and intended for single-use implantation. Once implanted, it is not designed for removal or reuse, aligning with standard practices for implantable pacemaker pulse-generators to ensure patient safety and sterility.

  • What regulatory pathway was followed for FDA clearance of this device, and when was the decision made?

    The Pulse Generator Model 688 received FDA 510(k) clearance under the traditional review pathway, with a decision date of January 30, 1984. The submission was classified under the Cardiovascular (CV) advisory committee and was deemed *Substantially Equivalent* (SESE) to a predicate device, as indicated in the regulatory records.

  • Are there any known compatibility considerations for this device, such as MRI use, that clinicians should be aware of?

    The Pulse Generator Model 688 does not have documented MRI compatibility in the available data. Clinicians should exercise caution when considering MRI procedures for patients with this device, as implantable pacemakers are generally contraindicated in MRI environments due to potential electromagnetic interference risks.